background image

LAUNCH 

UK

www.

launchtech

.co.uk

Pro series
Diagnostic leak Detector
V3.01EN

Part #3230001

Smoke 1

User Manual

The Smoke 1 can be used to find leaks in almost any closed system. The optional cap plug set, and adapter cone can be used 
to introduce smoke and seal numerous vehicle systems.

The Smoke1 can find hard to locate leaks in the passenger compartment areas.

Method.

Set the blower to maximum ensuring the it is not set to recirculate, this will pressurise the cabin. Introduce smoke around any 
suspect areas. Look for any turbulence in the smoke output caused by air leaking from the cabin. This will indicate the area of 
concern. This test must be carried out in a draught free location.

The Smoke 1 can also be used to find leaks in cooling systems, engines, transmissions, EGR valves, exhaust systems, vacuum 
systems and many others. 

Specification: 

3230001

Power supply:  12.4~14.5V

Flow rate: 

10 l/min

Flow control: 

N/A

Pressure control:  N/A 

Auto-off:  

5 minutes

Smoke tube: 

2.5 metre

Power cables 

2.3 metre’s

Smoke fluid: 

Pharmaceutical grade mineral oil 95% Organic solution with fluorescent                    

Dye 5%                   

Manufactured for Launch Tech UK Ltd
Huxley Close. Plymouth. Devon 01752 344989

www.launchtech.co.uk

Other Tests

Troubleshooting

No smoke

    

 Check power supply>12.5V

 

 

   

 Check correct polarity

 

 

   

 Check power cable for continuity

Power LED on

 

  

 Check for click from PCB switch when pressing start/stop button

 

 

   

 Check for air pressure

 

 

 

   

 Check for correct smoke fluid and level

Poor or erratic smoke delivery

 

 Battery must be fully charged 12.5~14.5V

 

 

   

 Oil residue build up in smoke tube, remove and blow through

Отзывы: