The Smoke 1 can be used to find leaks in almost any closed system. The optional cap plug set, and adapter cone can be used
to introduce smoke and seal numerous vehicle systems.
The Smoke1 can find hard to locate leaks in the passenger compartment areas.
Method.
Set the blower to maximum ensuring the it is not set to recirculate, this will pressurise the cabin. Introduce smoke around any
suspect areas. Look for any turbulence in the smoke output caused by air leaking from the cabin. This will indicate the area of
concern. This test must be carried out in a draught free location.
The Smoke 1 can also be used to find leaks in cooling systems, engines, transmissions, EGR valves, exhaust systems, vacuum
systems and many others.
Specification:
3230001
Power supply: 12.4~14.5V
Flow rate:
10 l/min
Flow control:
N/A
Pressure control: N/A
Auto-off:
5 minutes
Smoke tube:
2.5 metre
Power cables
2.3 metre’s
Smoke fluid:
Pharmaceutical grade mineral oil 95% Organic solution with fluorescent
Dye 5%
Manufactured for Launch Tech UK Ltd
Huxley Close. Plymouth. Devon 01752 344989
www.launchtech.co.uk
Other Tests
Troubleshooting
No smoke
•
Check power supply>12.5V
•
Check correct polarity
•
Check power cable for continuity
Power LED on
•
Check for click from PCB switch when pressing start/stop button
•
Check for air pressure
•
Check for correct smoke fluid and level
Poor or erratic smoke delivery
•
Battery must be fully charged 12.5~14.5V
•
Oil residue build up in smoke tube, remove and blow through