- 18 -
SETTING UNITS OF MEASURE
These are the available units of measure:
:
kilograms
:
grams
:
tons
:
pounds
: newtons
:
litres
:
bars
:
atmospheres
:
pieces
:
newton metres
: kilogram metres
:
other generic units of measure not included in the list
If the print function is enabled, the symbol corresponding to the selected unit of measure will be
printed after the measured value.
OUTPUTS AND INPUTS CONFIGURATION
OUTPUTS
-
OUTPUT 1: PRESET (for operation see
OPERATION SETTINGS
)
-
OUTPUT 2: SET (for operation see
OPERATION SETTINGS
)
-
OUTPUT 3: CYCLE END (the relay is closed to the achievement of Cycle End)
-
OUTPUT 4: ALARM (the relay is closed when an alarm is present)
-
OUTPUT 5: TOLERANCE (the relay is closed when the weight is out of tolerance)
INPUTS
-
INPUT 1: START
-
INPUT 2: STOP
-
INPUT 3 (default =
): It’s possible to select one of the following functions:
-
(NET/GROSS): by closing this input for no more than one second, it’s making an
operation of SEMI-AUTOMATIC TARE and the display will show the net weight. To display
the gross weight again, hold the NET/GROSS input closed for 3 seconds.
-
(SEMI-AUTOMATIC ZERO): by closing the input for no more than one second, the
weight is set to zero (see section
SEMI-AUTOMATIC ZERO (WEIGHT ZERO-SETTING
FOR SMALL VARIATIONS)
).
-
(APPROVAL):
the instrument starts the batching only after verifying that this input is
closed.
+
+
Содержание W200-C
Страница 16: ...11 BATCHING CONSTANTS it appears only if in constants TOTAL YES...
Страница 53: ......
Страница 54: ......
Страница 55: ......
Страница 56: ......