Proline Low-temperature Thermostats
34
Starting up
YACE0072 / 21.08.07
7.5 "Master"
menu
structure
1%21
Actual bath temperature
or actual value of
external temperature
Section 7.6.1
RDr
Set setpoint
Section 7.7.1
Os
Pump power
Section 7.7.3
Bml
Control Int/Ext
Section 7.7.4
LMDkt
Settings
Section 7.6.2
LMnet
Conf. Modules
Section 7.6.3
RDB
Protection system
Section 7.6.9
B/LM
Command
Section 7.6.3
B//
l
Cooling system
Section 7.6.10
@l@
Analog module
Section 8.4
pR
Conf. RS232/ 485
Section 8.3
c0a
Conf. digit. mod.
Section 8.5
O@pA-
Parameters
Section 7.6.4
O0c--
Control par.
Only internal or external
parameters are offered
depending on control
variable
Section 7.6.5 / 7.6.6
RgmY[
Show values
Section 7.6.8
B@K--
Pt100 calibration
Section 7.6.7
B@K 0
Offset int. Pt100
Section 7.8.7
cDE !
Works settgs. int. Pt
Section 7.8.8
B@K D
Offset ext. Pt100
Section 0
cDE D
Works settgs. ext. Pt
Section 7.8.10
TDp
Software version
Section 9.2.2
Rlp^G
Serial number Hi Word.
Section 9.2.3
Rlp^K
Serial number Lo Word.
Section 9.2.3
RrDKK
Control value of tempera.
controller. Section 9.2.4
rGD@c
Temp. of housing °C
Section 9.2.4
rGR
Temp. of heatsink °C
Section 9.2.4
E@l T
Fan voltage in V.
Section 9.2.4
0DEE
Mains curr. consumpt. in A
Section 9.2.4
T^RDB
Prot. syst. voltage in V.
Section 9.2.4
T13
Act. val. 24V voltage in V.
Section 9.2.4
OT 0
Current consumpt. pump I.
Section 9.2.4
OT O
Power consumpt. pump W
Section 9.2.4
OT l
Pump speed rpm.
Section 9.2.4
lE 4/
Mains frequency Hz
Section 9.2.4
lT
Mains volt. % of rated volt.
Section 9.2.4
KD
Bath level [cm]
Section 9.2.4
rD Or
Extern temp. Pt100
Section 9.2.4
rD@l@
Ext. temp. analog. interf.
Section 9.2.4
rDRDp
Ext.temp. RS232/485
Section 9.2.4
hRDr
Curr. controller setpoint.
Section 9.2.4
RDro-
Setpoint relat. to act.
val. Section 7.8.4
R
Setpoint resolution
Section 7.8.1
Rr@pr
Opern. w. mains fail.
Section 7.8.2
rhg
Upper temp. limit
Section 7.8.3
Bsp
Max. current consumpt.
Section 7.7.5
rhK
Lower temp. limit
Section 7.8.3
rXOF-
Detect type of unit.
Section 9.2.1
cDE
Works setting
Section 7.8.5
@scin
Signal settings.
Section 7.8.6
G^@
ll
Counter operating hours
Master complete
G^OT
Counter operating hours
Pump
rc
Int. damping time (Td)=
Section 7.13.1
^O
Int. proport.range (Xp)
Section 7.13.1
rl
Internal reset time (Tn)
Section 7.13.1
rs
Int. derivative time (Tv)
Section 7.13.1
rsc
Int. contr. par. auto/man.
Section 7.13.1
cDE
Works settings
Section 7.13.1
hO
External P-controller (Xpf)
Section 7.13.2
Dt
Ext. derivative time (Tve)
Section 7.13.2
Dc
Ext. damping time (Tde)
Section 7.13.2
Da
Ext.propor.range (Prop_E)
Section 7.13.2
Dr/K
Ext.correct. var. (K)
Section 7.13.2
D
Ext. contr.par. auto/ man.
Section 7.13.2
cDE
Works settings
Section 7.13.2
Dl
External reset time (Tne)
Section 7.13.2
DO
Ext. prop. factor (Kpe)
Section 7.13.2