background image

 

  

ECOLINE Staredition

 

 

6

 

Technical Data

 

27.06.2018/YACE0068 

 

The equipment is not rated for use under medical conditions according to DIN EN 60601-1 or IEC 601-1. 
 

Classification according to EMC requirements  

Equipment 

Immunity  

Emission class 

Network connection 

customer  

Calibration thermostat  

Ecoline 

Type 1  

according to 

DIN EN 61326-1 

Emission class B  

according to CISPR 11 

worldwide 

no restriction 

 

 

 

 

 

Instructions for Class A digital device, USA: 

Note:

 This equipment has been tested and found to comply with the limits for Class A digital device, 

pursuant to Part 15 of the FCC (Federal Communication Commission) Rules. These limits are designed to 
provide reasonable protection against harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if 
not installed and used in accordance with the instruction manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is likely to cause harmful interference in 
which case the user wi

ll be required to correct the interference at his own expense”.

 

Instructions for Class A digital device, Canada: 

“This Class A digital apparatus complies with Canadian ICES-003” (ICES = Interference Causing 
Equipment Standards).  
« Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada ».

 

 

Refrigerant and filling quantity

   

The cooling thermostat contains fluorinated greenhouse gases. 

 

Units 

RE 212 J 

RE 312 J 

Refrigerant 

--- 

R-404A 

R-404A 

maximum filling quantity  

kg 

0.22 

0.22 

GWP

(100a)

--- 

3922 

3922 

CO

2

 equivalent 

0.9 

0.9 

 

 

Global Warming Potential (GWP),   
Comparison CO

2

 = 1,0  

* Time span 100 years - according to IPCC IV 

 

Technical amendments reserved!

 

Содержание RE 212 J

Страница 1: ...Lauda Königshofen Germany release 06 2018 c replaces release 11 2016 V02 08 20156 b1 07 04 YACE0068 Phone 49 0 9343 503 0 Fax 49 0 9343 503 222 e mail info lauda de Internet http www lauda de Operating instructions Calibration thermostat RE 212 J RE 312 J Annex to manual RE 212 RE 312 YACE 0060 YACE 0065 ...

Страница 2: ......

Страница 3: ... immersion depth independent from the volume extension of the bath liquid an extremely good temperature accuracy and distribution of temperature There are pump connectors to connect other external closed circuits but won t be available if the thermostat is used for calibrating Side view Top view EU conformity The device complies with the basic health and safety requirements outline in the Directiv...

Страница 4: ... and fix it that way it rises 3 mm above the bath opening Refill the bath liquid only up to 15 mm underneath the bath opening and only at working temperature and switched off pump Recommendation for the adjustment of the cylindrical working chamber Switch the button for the distribution of the pump flow to ext see diagram Pos 1 Position maximum flow rate in the external circuit working chamber The...

Страница 5: ... V 60 Hz kW kW kW 2 25 2 25 1 3 2 25 2 25 1 3 Eff Cooling capacity with Ethanol at ambient temperature 20 C 20 C 0 C 20 C 30 C kW kW kW kW 0 30 0 23 0 13 0 04 0 30 0 23 0 13 0 04 Pump type Pressure pump with selection of 5 power stages Pump output max bar 0 4 Discharge pressure max L min 17 Pump connections for tubing mm Nipples dia 13 mm M16 x 1 Bath filling capacity max L 9 12 Bath opening B x T...

Страница 6: ...t This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Instructions for Class A ...

Отзывы: