PC3500TX Terminal Installation & User’s Guide - 9
Setup Mode – 177B Firmware
(For PayClock Pro 3.355G and earlier)
To Setup the PC3500TX’s Ethernet Communications
Setup Mode allows you to setup the terminal to communicate through the network with
the PayClock “TCP/IP Server”.
IMPORTANT! The PC3500TX terminal requires that the Terminal Manager module runs
with “TCP/IP Server” enabled.
♦
Locate the Test/Use switch on the back of the terminal.
♦
Slide the switch into the TEST position (away from the modular jacks).
♦
With the “TEST MODE” message in the terminal display, press the CLEAR key five
(5) times. The message “RESTART MODE” appears on the top line of the display.
Press the ENTER key three (3) times to clear all memory prior to setting up the
terminal. After resetting, the terminal will again display “TEST MODE”.
NOTE:
Skipping this step greatly increases the chances of unreliable test results during
the setup of the terminal.
♦
Press the CLEAR key one (1) time.
The terminal displays “
SETUP MODE”
on the top line followed by:
TERM 000.000.000.000
displayed for one (1) second
HOST 000.000.000.000
displayed for one (1) second
GATE 000.000.000.000
displayed for one (1) second
(This message will only display if the gate address was previously setup)
MASK 000.000.000.000
displayed for one (1) second
NOTE:
The above sequence will repeat itself until either the CLEAR or ENTER key is
pressed. Pressing the CLEAR key will bypass the Setup Mode. Pressing the ENTER key
will enable the Setup Mode.