LTRx-512 Installer’s Guide
14
[#]
SYSTEM TYPE CODE: NN
If you are using an LTR8-512 or LTR8-512M and you chose a
CLOCK1 type other than 00, you will see
SELECT CLK2 CODE: NN
[0]..[9]
Enter the code for CLOCK2, or 00, if none
[#]
PRESS [#] IF CORRECT
[#]
Press [#] to accept
-or-
[*]
Press [*] to cancel and try again
Manual Bell Control
•
Use Function [3] to manually turn on bell circuits
Press
Display
[#]
SELECT FUNCTION CODE
[3]
[3]=MANUAL BELL CTRL
[#]
MANUAL BELL CONTROLS
1-2-3-4-5-6-7-8
PRESS AND HOLD [#]
TO EXECUTE.[*]TO END
[1]..[8]
Enter the circuit numbers that you want to test. When you see the
circuits you want, press and hold [#]. Those circuits will turn on
their relays, as shown by the green panel lights. When you release
the [#], the circuits will turn off their relays. You can now choose
and test other circuits or press [*] to quit
Note: Only circuits setup as Bell Zones will appear. If you have an
LTR8-512 with a single clock system attached, you will only see
circuits 1-6. If you have an LTR4-512 with a single clock system
attached, you will only see circuits 1-2
[*]
Return to time and date display