Electrical Wiring & Bonding
The system must be bonded to meet the National Electrical Code. Bond both tracks to the mechanism by attaching a bonding lug to the
guide screw and running a #8 solid copper bond wire to the mechanism. Bond the lid to the mechanism by drilling a hole in the lid at
either end of the lid and attaching a bonding lug in each position and bonding it to the mechanism. All brackets and any other metal over
4” long should likewise be bonded to the mechanism. There should be a bond wire from the equipment pad inside the cover box. Attach
this bond wire to the mechanism to complete the bonding requirement. Note: Builder is responsible to bring proper electrical lines, conduit
and bonding to the mechanism. Electrical wiring diagram and details are shown
below
.
Wiring
t
he Electrical Switch
The control switch mus
t
be mounted in an all
-
weather box, in a location where 100% of the pool is visible.
Connect the control switch according the diagram below.
© Latham Pool Products, Inc. 2018. All rights reserved.
12 of 19