Lastolite lumen 8 Скачать руководство пользователя страница 4

It is recommended that the F200/F400 be used with medium-weight lighting stands with standard

16mm male spigots. The stands must be stable when fitted with the unit and reflectors, umbrellas or

soft-boxes and when they are extended to full height. If the stand and unit fall over, severe damage to

the flash-unit is likely. 

To release the Lighting Stand Clamp, turn the Tilt handle anticlockwise.

Swing the clamp to a new position then tighten. The Tilt handle can be

placed in any position by lifting it up against its spring, turning then

releasing.

Place the unit on the stand; loosen the Clamp Screw if required.

Retighten the screw so that it fits the unit securely to the stand's spigot.

The unit can now be tilted into any position. It is recommended that the

unit's handle be held with one hand while adjusting the tilt with the

other. 

OPERATING PRECAUTIONS/SAFETY

The F200/400 units are designed for indoor use only and for connection to domestic 220-240VAC single

phase only. The unit must be operated with an adequate ground/earth, as normally found in three

connection mains plugs. For safety, a continuous ground connection to the camera is provided by the

low voltage sync. circuit and sync. cable.

Do not operate in damp conditions or with wet hands. High voltage is present inside, even when

disconnected from the mains. Do not open the unit; there are no user-serviceable parts inside.

Use only the recommended mains cable (supplied) and only the recommended modelling lamps.

Do not fire the flash faster or for more times within a period than recommended (refer to the unit's

specifications). Do not place inflammable material near the modelling lamp or flash-tube. Do not

enclose the unit so that the free-flow of air is compromised.

5

Fitting The Unit To a Light Stand

Содержание lumen 8

Страница 1: ...User Manual...

Страница 2: ...ctor 2 Reflector Release Button 3 Slave Cell 4 Lighting Stand Clamp 5 Clamp Screw 6 Umbrella Clamp Screw 7 Umbrella Clamp 8 Reflector Umbrella Slot 9 Inner Reflector 10 Flash Tube 11 Reflector Bayonet...

Страница 3: ...Power Socket 14 Fuseholder Fuses 15 Power On Off 16 Modelling Lamp On 17 Modelling Lamp Full 18 Slave Cell On 19 Beeper Sounder On 20 Flash Test Button 21 Ready to Fire Indicator 22 Flash Modelling P...

Страница 4: ...th one hand while adjusting the tilt with the other OPERATING PRECAUTIONS SAFETY The F200 400 units are designed for indoor use only and for connection to domestic 220 240VAC single phase only The uni...

Страница 5: ...sory if it is possible Line up the reflector bayonets over the slots as shown If an umbrella reflector is also going to be used orientate the reflector so that the oblong reflector slot is at the bott...

Страница 6: ...are when fitting a lamp 11 The ES screw socket may require the lamp to be fully screwed down in order to make contact If a new lamp fails to light check that it is fully screwed down 12 Take care not...

Страница 7: ...his function the photographer can easily check from the camera position that all units have flashed When the Full switch is switched up the modelling lamp function changes the lamp will stay on when t...

Страница 8: ...ll increase the flash by another one stop approximately double the light Mid way positions can be used for increases in light of less than one stop the control has small click indents to aid fractiona...

Страница 9: ...be flashed Do not try to fire the unit before this indicator is lit When firing the unit at short intervals refer to the maximum advisable flash rate firing the unit too quickly can cause the flash tu...

Страница 10: ...3AL For convenience all flash units are provided with a spare fuse built into the fuse holder The following procedure must be taken to replace the fuse 11 Fuse Replacement The fuse holder is accessed...

Страница 11: ...amp Modes Full Prop Off Full Prop Off Auto Dump Yes Yes Colour Temperature 5300 5600k 5300 5600k Slave Cell Yes 10 metres Yes 10 metres Triggering Methods Sync Test Slave Sync Test Slave Main Operatin...