11

Operation

1. The temperature controller(thermostat) is located on the upper left of the back side
   of the cabinet interior.

2. The controller has been preset to "NORMAL" at the factory.

3. Set the control-knob toward "COOL" for higher temperature and "COLD" for lower
    temperature.

4. The thermostat controls compressor's ON/OFF by sensing inside temperatures of 
    cabinet.

5. LUCR, LST, LMT Series : Off-cycle defrost
    LUCF Series : Heating defrost

6. When turning it off, use the POWER SWITCH on top.

Operation

POWER SWITCH

Содержание LMT27

Страница 1: ...s Installation Operation Manual Please read this manual completely before attempting to install or operate this equipment R512B 252 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS Visit us on th...

Страница 2: ...rior of the package and skid or container Any damage should be noted on the delivery slip and reported to seller immediately 2 If damaged open and inspect the contents with the carrier 3 WITHIN 48 HOU...

Страница 3: ...sions Including 4 Casters mm W 700 923 1227 1533 1839 D 762 762 762 762 762 H 912 912 912 912 912 Net Weight kg 61 74 87 103 120 Type of refrigeration system Indirect cooling Fan blowing Control Therm...

Страница 4: ...LUCR60 D4 LUCR72 D6 Capacity Liter 200 372 474 572 Exterior Dimensions Including 4 Casters mm W 700 1227 1533 1839 D 762 762 762 762 H 912 912 912 912 Net Weight kg 66 108 126 150 Type of refrigeratio...

Страница 5: ...uding 4 Casters mm W 700 923 1227 1533 1839 D 762 762 762 762 762 H 912 912 912 912 912 Net Weight kg 64 78 91 108 124 Type of refrigeration system Indirect cooling Fan blowing Control Thermostat Numb...

Страница 6: ...62 762 762 H 1082 1082 1082 1082 1082 Net Weight kg 67 82 100 112 129 Type of refrigeration system Indirect cooling Fan blowing Control Thermostat Number of Shelves 1 2 2 2 3 Number of doors 1 2 2 2 3...

Страница 7: ...72 D6 Capacity Liter 200 372 474 572 Exterior Dimensions Including 4 Casters mm W 700 1227 1533 1839 D 762 762 762 762 H 1082 1082 1082 1082 Net Weight kg 72 121 135 160 Type of refrigeration system I...

Страница 8: ...ting board 901 H 1122 1122 1122 1122 1122 Net Weight kg 76 92 110 123 141 Type of refrigeration system Indirect cooling Fan blowing Control Thermostat Number of Shelves 1 2 2 2 3 Number of doors 1 2 2...

Страница 9: ...OR USAGE ONLY This equipment is intended for indoor use only 5 STABILIZING Make sure the unit is installed on a solid surface with the front wheels locked while in use 6 LEVELING Make sure that the un...

Страница 10: ...ct power to unit Take off rear cover at the bottom by removing screws Clean off accumulated dirt from condensing coil and fan blades with a soft brush Make sure to brush in the direction of the fins a...

Страница 11: ...preset to NORMAL at the factory 3 Set the control knob toward COOL for higher temperature and COLD for lower temperature 4 The thermostat controls compressor s ON OFF by sensing inside temperatures of...

Страница 12: ...The door is opened too frequently Loading of too much warm or moist product Not enough ventilation Move the unit in a well Ventilated place with at least 7 Inches of clearance on all sides Condenser i...

Страница 13: ...13 Installing Casters 1 Remove the outer packing 2 Install the castors as illustrated 3 Maker sure that the castors with brakes are installed at the front of the unit...

Страница 14: ...14 MEMO...

Страница 15: ...15 MEMO...

Страница 16: ...Manufacturer DAEYEONG E B ANSAN SI GYEONGGI DO REPUBLIC OF KOREA TEL 82 31 491 1091 FAX 82 31 491 0325 www daeyeong co kr...