16
17
Install bin switch in the following order by referring to Fig 3.
1. When the front panel is removed, enclosed within the machine will be a bin switch,
packed in a plastic.
2. To remove the front panel, refer to “2.5 How to Remove Panel”.
3. Affix the bin switch to the right bottom of the ice machine with fourthumbscrews,
enclosed withthe switch.
4. Position the cable of bin switch into the“J”-type slot of the front supporter by releasing it.
While installing the cable ensure it is not blocking any ice are dropping into the bin.
5. After affixing the cable alongside the Pump motor harness connect it to the blue connector at
the top frame.
2.7 Bin Switch Installation
WARNING
- Bin switch should be equipped before operating the ice machine.
If it is not properly equipped, it might cause a breakdown or malfunction during ice storage.
Fig 3
Thumbscrew
“J” Slot
Supporter front
Pump motor
harness
2.8.1
Water Supply
-Depending on the location where the ice machine is installed, the ice machine may
require a water filtration system to prevent formation of scale and removing impurities and
chlorine from the water supply.
2.8.2
Water Supply Line
Refer to following instructions for installing the water supply line.
- Do not connect a hot water system to the ice machine.
- Water pressure must be between 30 ~ 100 psig(206.8-689.4kPa).
- Water supply line must have a shut off valve.
- Water supply line must be insulated to prevent condensation.
2.8.3
Drainage Line
To prevent backflow of the ice machine and storage container, refer to following
instructions for install a drainage line.
- For adequate drainage, a gradient of 1 inch for every 3.3 feet(2.5cm per meter) is needed.
- Do not install any trap.
- Do not connect drainage pipe directly into the sewage pipe.
- There must be a minimum of a 2 inch (50mm)air gap vertically between end of the drainage
pipe and the drain hole.
- Must install a vent.
- Do not combine drain lines for the machine head and the ice storage bin.
- The machine applies gravity drains and does not prevent counter-flow. If you want parts for preventing it,
they must be purchased separately.
2.8 Water Supply & Drain Connections
WARNING
- Installation of water supply and pipe system must be done in accordance to
local, state and federal laws and regulations.
- The ice machine is to be installed with adequate backflow protection to comply
with applicable local, state and federal laws and regulations.
- Water pipe work must be done by a qualified service technicians.
Содержание LMI-300A
Страница 1: ...InstallationandUser sManual LMI 300A LMI 500A LMI 650A LMI 900A ver 202007_01 I512A 261 ...
Страница 7: ...7 1 2 Product Dimensions 300A 500A FRONT TOP SIDE REAR ...
Страница 8: ...8 650A FRONT TOP SIDE REAR ...
Страница 9: ...9 900A FRONT TOP SIDE REAR ...
Страница 34: ...34 MEMO ...
Страница 35: ...35 MEMO ...