Functions of pushbuttons during programming monitor number:

PROG 

- entering programming mode

CONVERSATION

- entering programmed value

LOCK

        - confirmation of entered value, passing to next programming stage

Arrangement of pushbuttons and signalling diodes is shown on dwg. 1 and 2.

Programming new number requires the following activities:

3.1. We should press three times pushbutton PROG on a plate in the monitor rear part (see

dwg.2) – this should be done within 3 sec. Monitor passes to programming mode which
is siganalled by a short flash of LED1 and LED2 diodes.

3.2. 

Setting number of hundreds

. Pushbutton CONVERSATION should be pressed as many

times as there are hundreds in the programmed number (0,1 or 2). Each pressing is
signalled by flashing of LED2 diode. Then entering number of hundreds should be
finished by pressing pushbutton LOCK which will be confirmed by longer flashing of
a diode. If the number of hundreds is equal to 0 (programmed number smaller than
100)  pushbutton LOCK should be pressed immediately and the next step should be
realized – entering the number of tens.

3.3. 

Setting number of tens

. Pushbutton CONVERSATION should be pressed as many

times as there are tens in the programmed number (0,1 or 2). Each pressing is signalled
by flashing of LED2 diode. Then entering number of tens should be finished by pressing
pushbutton LOCK which will be confirmed by longer flashing of a diode. If the number
of tens is equal to 0 pushbutton LOCK should be pressed immediately and the next
step should be realized – entering the number of unities.

3.4. 

Setting number of unities.

 Pushbutton CONVERSATION should be pressed as many

times as there are unities in the programmed number. Each pressing is signalled by
flashing of LED2 diode. Then entering number of unities should be finished by pressing
pushbutton LOCK which will be confirmed by longer flashing of a diode. If the number
of unities is equal to 0  pushbutton LOCK should be pressed immediately.

3.5. 

Finishing the programming procedure. Checking the number.

      LED2 starts flashing as many times as there are hundreds, tens and unities in the

programmed number. Longer break means passing to next digit in the programmed
number while longer flashing of LED1 means a zero value of a given digit. After finishing
reproducing the programmed number LED1 and LED2 will light at the same time, then
one diode will extinguish depending to volume level of acoustic signal before starting
the programming procedure.

3.6. If the number is not programmed within 30 sec the procedure will be stopped automatically

and monitor number will not be changed.

4. Checking the monitor number

To check the monitor programmed number pushbuttons CONVERSATION and LOCK should
be pressed at the same time in waiting mode (no audio or video connection). LED1 and
LED2 will light for a moment then the programmed number will be reproduced according
to item 3.5.

Page 

5

 LASKOMEX PPUH, ul. D¹browskiego 249, 93-231 £ódŸ, tel. (42) 671 88 00, fax (42) 671 88 88, e-mail: [email protected], http://www.laskomex.com.pl

MVC-6650

Installation and activation

Содержание MVC-6650

Страница 1: ...Installation and activation MVC 6650...

Страница 2: ...tor hanging the number should be programmed description below in item 3 Monitor can be supplied directly from individual power supply adaptor 13 5V DC 1A dwg 6 or from video signal distributor CVR 2 t...

Страница 3: ...249 93 231 d tel 42 671 88 00 fax 42 671 88 88 e mail laskomex laskomex com pl http www laskomex com pl MVC 6650 Installation and activation Pin for connecting floor panel or additional camera Pin fo...

Страница 4: ...CK pushbutton CONVERSATION is used for changing calling volume Four volume modes are possible quiet intermediate loud and increasing three short signals of increasing frequency After having made the c...

Страница 5: ...0 pushbutton LOCK should be pressed immediately and the next step should be realized entering the number of unities 3 4 Setting number of unities Pushbutton CONVERSATION should be pressed as many time...

Страница 6: ...ed and held for a moment until LED1 or LED2 is changed approx 2 sec LED1 means loud signal LED2 muffled and flashing LED2 means switched off signalling no possibility of making connection or monitorin...

Страница 7: ...iego 249 93 231 d tel 42 671 88 00 fax 42 671 88 88 e mail laskomex laskomex com pl http www laskomex com pl B1 C1 C1 GB GND 15V AUD CC2 GC GS VS 1C L L 1C L L GND 15V C L L C AC AC C C AC AC CC4 CC3...

Страница 8: ...l recycling saves raw materials and reduces generating of wastes This product was marked with a symbol of crossed dustbin according to European Directive 2002 96 WE on used electric and electronic equ...