CONTENTS

1.   Safety and usage conditions

3

2.   Installation of electronic cassette and power supply adaptor

3

3.   Configuration

3

4.   Adjustment

4

5.   Programming of entry phone

5

6.   Restore the initial settings

7

7.   Conformity with previous versions

8

8.   Faults messages

8

9.   Technical data

8

10. Descriptions of terminals

9

11. Dimensions of elements

9

12. Selection of wires and connection diagrams

  

        10

Changes in software (electronic cassette):

- Added function that turns off the camera in an external panel during

the call - an additional option "b" in the calling options in individual
settings.

- Changed name of parameter EUC on CAon
- Added parameter CAin that determines the supported video inputs

of CVP-x switch

- Added parameter CAtP that determines time interval of switching

picture

- Added the ability to cooperate with the CVP-2 switch
- Removed P-7 procedure (electro-catch test)
- Moved MLX support to P-7 - exchange of data requires an administrator

password

- Added function of testing the electro-catch control frequency after

changing the Fry parameter

- Increased entrance preview time after the entry of coded lock code

- Added keypad blocking function during RFID reading
- New parameters LdP and NbP in H version of electronic cassette in

procedure P-1

- New parameter APo in procedure P-2
- Removed parameters t1t, F1 and F2 from procedure P-1
- Additional numbers are priority numbers
- If local number is in the range of serviced numbers and is turn off,

than is automatically treated as unserviced number - important for
LdP

- Added function that turns off confirmation the use of coded lock and

electronic keys for individual occupant - additional option "P" in Calling
option (parameter No. 4 in procedure P-5)

- Added parameter CHA in procedure P-2.
- Changed name of parameter Ldn on Un in procedure P-1.
- Changed names of parameters ibE and ibA on idE and idA in procedure

P-2.

- Increased speed of searching electronic keys

- Added 10 additional numbers out of serviced range
- Added DJ function
- Improve P-4-0 function in H version of electronic cassette
- Added automatic door open function - additional option "d" in Entrance

service (parameter No. 5 in procedure P-5)

Software
version

Version
release date

Changes

v6_8

v6_6

v6_7

11-2010

06-2010

01-2010

Содержание EC-2502

Страница 1: ...DIGITAL ENTRY PHONE SYSTEM INSTALLATION SERVICE AND PROGRAMMING MANUAL OF ELECTRONIC CASSETTE EC 2502...

Страница 2: ...or password Added function of testing the electro catch control frequency after changing the Fry parameter Increased entrance preview time after the entry of coded lock code Added keypad blocking func...

Страница 3: ...e place where the power supply adapter is mounted supply from power network should be routed Electronic cassette casing is fixed to the base by means of two screws Wire ends from feeding transformer s...

Страница 4: ...sed jumper should be put on joint J3 and operation frequency parameter FrY should be set on 0 see figure 2 In case electro catch is used jumper should be removed from joint J3 Figure 2 Selection of el...

Страница 5: ...r CHA idE idA CAon 3C Ent NbL 1 1 0 0 1 1 1 0 0 1 1 0 0 1 1 U H U H U H U H U H U U U U U H U H U H U H U H Sound signal of sign selected from the keyboard Multitone signaling of sign selected from th...

Страница 6: ...ddition of key without assigned to the apartment Addition of key with assigned to the apartment Addition of key on the selected item in memory Deleting the key Deleting the key assigned to the apartme...

Страница 7: ...ettings the cassette was configured as EC 2502 H after finishing of this operation the cassette will still operate in this mode Pushbutton RESET is used for momentary stopping the operation of a proce...

Страница 8: ...ed of EC 3100 CP 3100 and supplier Subordinate entrances should be connected in such a way as if entry phone CD 2502 line L L was installed at the main entrance If CD 3100 is connected with CD 2501 mo...

Страница 9: ...supply communication line between cassette H and U KZ output of key switching on el catch if works as EC 2502H VZ electro catch supply L uniphone line if works as EC 2502U GZ mass of key switching on...

Страница 10: ...5 V AC 0 8 A White Brown AC2 AC1 CP xxxx 12 V AC 1 A Brown Brown K6 K5 K4 K2 K3 K1 X GX GZ VZ KZ GZA VZA VP GP AC4 AC3 C C EC 2502 U 230 V AC 14 5 V AC 0 8 A White Brown AC2 AC1 CP xxxx 12 V AC 1 A AC...

Страница 11: ...MSpw YTKSY UTP LAN T11 XzTKMXpw YTKSY UTP LAN T11 XzTKMXpw Clamps Distance CP EC 15m 30m K1 K4 K1 K4 0 5mm 2x 0 5mm K2 K6 K2 K6 0 5mm 0 5mm K3 K3 3x 0 5mm 5x 0 5mm K5 K5 2x 0 5mm 2x 0 5mm X GX X GS 0...

Страница 12: ...d electric equipment considerably contributes to the protection of human health and life as well as protection of natural environment Return of packaging materials for the material recycling saves raw...

Отзывы: