background image

 User manual: CS-500RGBV 

Rev: 08/2009 

page5 of 6 

 

Accessories:

 power cable, key switch, interlock plug, manual 

 

Input voltage:

 AC 100~240V 50/60Hz 

 

Power consumption:

 50W 

 

Size:

 300 x 240 x 150mm (W x D x H) 

 

Weight:

 3.8kg 

 

Operating temperature:

 10°-35°C 

ILDA signal 

Pin out of the standard ILDA signal: 

1 Scanner X+  

-10V..+10V 

14 X- 

+10V..-10V 

2 Scanner Y+  

-10V..+10V 

15 Y- 

+10V..-10V 

3 Intensity/B 

 0V..+2.5V 

16 Intensity/Blanking- 

0..-2.5V 

4 Interlock A 

 

17 Interlock B 

5 Red+  

0..2.5V 

18 Red- 

0..-2.5V 

6 Green+  

0..2.5V 

19 Green- 

0..2.5V 

7 Blue+  

0..2.5V 

20 Blue- 

0..-2.5V 

8 – 12 Not used 

 

23-24 Not used 

13 S5V, max. 20 mA 

25 GND Signal ground 

Trouble shooting 

No beam: emergency switch/dongle not connected. 
Low output: clean mirrors/window 
Musicmode not working: wrong DIP switch setting 
 

Sensitivity too low 

No DMX control: wrong DIP switch setting 
 

ILDA connected 

Laser does not switch to ILDA mode:  

 

The interface does not connect pins 4 and 17 (Interlock) of the IDLA signal. See interface 

manual 

 

The cable does not connect pins 4 and 17. Use a cable that connects pins 4 and 17. 

 

Use an adapter that connects pins 4 and 17. 

Please note 

This device has left our premises in absolutely perfect condition. In order to maintain 
this condition and to ensure a safe operation, it is absolutely necessary for the user 
to follow the safety instructions and warning notes written in this user manual. 

Laserworld cannot be made liable for damages caused by incorrect installations and 
unskilled operation! 

Отзывы: