Operating temperature is 10~35

°C

. Let laser cool off 10minutes after 2 hours of operation, 

to ensure maximum lifetime for the diode. 
Distance between laser aperture and projection screen should be not less than 1 meter. 
Do not turn device on and immediately off again frequently. 
Do not look into the laser beam directly, especially not with optical instruments. 

Do not touch the device with wet hands. 

When the laser diode becomes dim or broken, please contact your dealer timely. 
When returning laser to dealer/manufacturer always use original packaging.

 

Maintenance should be performed every 15-day period. Use a sponge with alcohol, rather 
than wet cloth or other chemical liquid, to clean the mirror. 

Using the laser 

Make sure the correct voltage is used. Connect mains. Connect an emergency switch to the 
remote connector on the backside. Turn key switch to on position. Depending on the mode 
selected (see below), laser light should come out of the opening on the front panel – be 
careful. 

Control panel 

Operating modes 

The following operating modes can be selected from the DIP switch on the backside of the 
device: 
DIP switch 1-10 

Mode 

1,0,0,0,0,0,0,0,1,0 

Music active, beam effects 

0,1,0,0,0,0,0,0,1,0 

Music active, animations 

1,0,0,0,0,0,0,0,0,0 

Automatic mode / beam effects 

0,1,0,0,0,0,0,0,0,0 

Automatic mode / animations 

x,x,x,x,x,x,x,x,x,1 

DMX 

 

“Music activ”:

 patterns are changed/animated to the beat of the music. Sensitivity can be 

adjusted with the knob on the back of the device. 

“Automatic mode”:

 patterns are changed automatically 

“DMX“:

 DMX512 Modus-. Use the first 9 switches to select the address: 

 

 

16 

32 

64 

128 

256 

e.g. 

1000 0000 01, DMX mode address 1 (1+0+0+0+0+0+0+0+0+0) 

 

0010 0100 01, DMX mode address 36 (0+0+4+0+0+32+0+0+0)

 

ILDA mode 

When an ILDA compatible interface is connected to the laser, the laser is automatically 
switched to ILDA mode. Output is then controlled from a PC running software.  

Safety switch: laser on/off 

Remotelock: connect emergency switch. If 
no emergency switch is connected use the 
9 pin plug supplied. 

DIP switch: DMX address/mode selection 
(see below) 

DMX 512 in/out 

Music mode: sensitivity 

Microphone 

Содержание CS-400G

Страница 1: ...y before use Contents SAFETY INSTRUCTIONS 2 OPERATING THE LASER 2 Using the laser 3 Control panel 3 Operating modes 3 ILDA mode 3 DMX mode 4 Maintenance cleaning 4 Technical specifications 5 Trouble shooting 5 Please note 5 EU declaration of conformity 6 ...

Страница 2: ...els supplied with a key switch to prevent unauthorized use warning labels and aperture labels affixed to the laser Installation safety Prior to installation and operation of the laser the paths of the beams and effects should be considered particularly with respect to how they will reach the audience If direct audience scanning is desired then the laser energy in the effects needs to be considered...

Страница 3: ...the front panel be careful Control panel Operating modes The following operating modes can be selected from the DIP switch on the backside of the device DIP switch 1 10 Mode 1 0 0 0 0 0 0 0 1 0 Music active beam effects 0 1 0 0 0 0 0 0 1 0 Music active animations 1 0 0 0 0 0 0 0 0 0 Automatic mode beam effects 0 1 0 0 0 0 0 0 0 0 Automatic mode animations x x x x x x x x x 1 DMX Music activ patter...

Страница 4: ...tern model pattern D selection 0 51 A B C D pattern be controlled simultaneou 52 103 Pattern A control effect 104 155 Pattern B control effect 156 207 Pattern C control effect 208 255 Pattern D control effect 0 is the turn off laser SHOW part editing function CH6 Multiple channel 0 255 1 255is the turn on laser SHOW part editing function 1 127 Angel rotating selection 15CH speed adjustment 128 191...

Страница 5: ...tch dongle not connected Low output clean mirrors window Musicmode not working wrong DIP switch setting Sensitivity too low No DMX control wrong DIP switch setting ILDA connected Laser does not switch to ILDA mode The interface does not connect pins 4 and 17 Interlock of the IDLA signal See interface manual The cable does not connect pins 4 and 17 Use a cable that connects pins 4 and 17 Use an ada...

Страница 6: ...urthermore the device is verified in correspondence to the laser class regulations DIN EN 60825 1 if properly set up according to the upper mentioned laser safety regulation After installing the device an inspection and official approval is indispensable for the overall setup The inspection must follow the european guidelines EN 60825 1 and corresponding regulations for the prevention of accidents...

Отзывы: