background image

12

CARE AND MAINTENANCE

 This is a precision measuring instrument 

and should always be handled with care and 
transported within the carry case provided. 

 Always slide the locking switch to the “off” 

position when transporting the instrument 
or moving around the job site.

 Whenever possible, store the instrument 

in a dry, shady location.

 Calibration of the instrument is 

recommended: every six months, if ongoing 
accurate levelling is required, or an impact 
has occurred.

 The operator should check the accuracy 

of the instrument before precision levelling 
is attempted. Failure to do so may result in 
inaccurate measurements.

 Clean the instrument with a dry, soft cloth 

after use in dusty, damp or wet conditions 
before storing.

 Smudges and fingerprints may be 

removed with a damp tissue or a soft, lint-
free cloth.

Содержание CL3 HYBRID

Страница 1: ...C L 3 H Y B R I D M U LT I L I N E L A S E R I N S T R U C T I O N M A N U A L...

Страница 2: ...d for your model Tool service must be performed only by qualified repair personnel Repairs service or maintenance performed by unqualified personnel will void the warranty Only approved and authorised...

Страница 3: ...securely on a level surface Damage to the laser or serious injury could result if the laser falls WARNING DO NOT DISASSEMBLE THE LASER There are no user serviceable parts inside Disassembling the lase...

Страница 4: ...ollowing items are included with your laser level If anything is missing please contact your retailer 2x laser targets INCHES CM 1 1 2 3 4 5 6 7 2 3 INCHES CM 1 1 2 3 4 5 6 7 2 3 The carry case contai...

Страница 5: ...5 LASER OVERVIEW Vertical laser port Horizontal laser port 1 4 tripod thread Control panel Power locking switch Battery door cover...

Страница 6: ...6 LASER OVERVIEW CONTROL PANEL Line mode Battery indicator Pulse mode Pulse mode indicator...

Страница 7: ...recommended that a hybrid line detector is used with this instrument for compatiblity with both the red and green laser beams i i Speaker Sound on off LED speaker indicator Laser sensor Power Bubble...

Страница 8: ...nsure the location is clear of traffic Place the instrument on a level surface such as a bench or mount The instrument is powered by four AA alkaline batteries Remove the battery cover door and the ba...

Страница 9: ...tch off and emit a beeping sound repeatedly If this occurs reposition the instrument onto a level surface until the instrument can level off Press the line mode button on the control panel to cycle th...

Страница 10: ...etection mode button to alternate between fine and course detection Hold the detector upright for horizontal beams Rotate the detector 90 for vertical beams The LED direction indicators will indicate...

Страница 11: ...e clean and not bent Laser does not remain on for long periods of use Check the batteries Check the battery compartment for signs of damage Ensure they are clean and not bent Laser does not level off...

Страница 12: ...rument in a dry shady location Calibration of the instrument is recommended every six months if ongoing accurate levelling is required or an impact has occurred The operator should check the accuracy...

Страница 13: ...y other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major fail...

Страница 14: ...14 To assist you with any queries or technical questions please contact customer support Australia 1300 658 338 New Zealand 0800 367 527 CUSTOMER SUPPORT...

Страница 15: ...1220 Warranty 3 Years Accuracy 2mm at 10m Operating range 50m with optional detector Levelling range 4 Laser class 2 Red 3 Green Battery life 10 hours Battery type 4x 1 5v AA Vertical lines 2 Horizont...

Страница 16: ...www spoton com au...

Отзывы: