PLMNL0286 REV. B, Effective Date: 06/06/19
12
FiberMINI
®
with Auto Focus (AF) Operation Manual
3.1.4 Ethernet / IP Control Box
(PLCSA0083)
There are (6) connection locations for
the Ethernet / IP control box.
1. Insert the male end of the control
cable into the 14-pin connection on
the electrical control box (no label).
2. Connect the USB cable
(PLCAB0718) to the connection on
the control box labeled USB.
The USB port provides the
interface connection
between the FiberMINI
®
AF and a computer. Laser
Mechanisms provides PC
software called FiberMINI
®
Monitor that allows
monitoring of the head and
changing of the settings.
3. Connect the optional user-supplied
Step/Direction input into the 15 pin
D-sub connector on the control box
(no label). See
more details.
4. Connect the user-supplied, 24V DC
power source to the three position
terminal block on the control box
labeled with +24V, 0V and Ground.
5. Connections to your system are
made through the 16 position
terminal block on the control box.
6. Connect the user-supplied network
cable to the Ethernet / IP Industrial
Network module. See
for more details.
Figure 15