background image

• Select “Super-Deep” (SET button) for thick wooden panels

and floor constructions (parquet etc.), max. measuring
depth 6 cm.

• 

Place the tool against the wall. 

LED CAL (3) flashes: Press the calibration button (7) and
wait until calibration is completed. CAL OK: LED 

CAL 

(3)

lights permanently.

Move the tool slowly across the surface.

IMPORTANT: 

The device must be in contact with the wall all

the time while measuring in StudScan-Mode. AC-Mode see
next page.

Tip 1: The position between the two markings is the mid-

point of the stud. 

Tip 2: The position where you start is important: First place

the tool in a position where you know there is no stud.
Otherwise, the LED CAL (3) will blink. To verify: Move
the tool to another position a few centimetres away
and start measuring again. 

Tip 3: The maximum display does not light up, even though

the LE display shows a reading. As soon as the most
intense display appears, the tool is over the edge of the
stud. Mark this point. Alternatively, increase the measu-
ring depth (SET button). 

Tip 4: To avoid interference while scanning, keep your free

hand and other objects at least 15 cm away from the
StarFinder. 

Tip 5: The StarFinder will only find the outside edge of double

studs and headers which may be fitted around doors,
windows and corners. 

StarFinder

ENGLISH

8

Then scan for the
other edge of the
stud.

Slide the tool sideways across the wall.
When the maximum display appears, you
have reached the edge of the stud.

Содержание StarFinder

Страница 1: ...nde ledninger D tection de c bles Localizaci n de cables Localizzazione di cavi elettrici Lokalizowanie przewod w Stud Scan AC Scan 4 cm Metall Metal Metaal Metal M tal Metal Metallo Metal Holz Wood H...

Страница 2: ......

Страница 3: ...epth B AC SCAN For localising live wires directly beneath the pla ster or behind wooden panels and other non metallic panelling It is not possible to detect live wires in dry walls with metal studs 4...

Страница 4: ...e is no stud Otherwise the LED CAL 3 will blink To verify Move the tool to another position a few centimetres away and start measuring again Tip 3 The maximum display does not light up even though the...

Страница 5: ...switch off the power supply when working near electric wires SPECIAL THINGS TO NOTE WITH VARIOUS MATERIALS It may not be possible to detect wooden studs or joists through the following materials Ceram...

Страница 6: ...t To achieve maximum sensitivity start by placing the device in a position which is known not to be near live wires Tip 5 With the Set Button 4 the sensivity can be adjusted The highest sensivity max...

Страница 7: ...ltiFinder Pro Art Nr 080 960A MeterMaster Pro Laser Art Nr 080 930A AQua Master AQM Pro 200 Art Nr 029 01 00A Metal Scan 5 cm AC Scan 2 cm 110 220 Volt 10 cm 1 cm 3 cm 4 cm Stud Scan www laserliner co...

Страница 8: ...ione di travi 3 Localizzazione di cavit 4 Sicurezza nella scelta del punto in cui praticare il foro Elektroniczny przyrz d lokalizacyjny 1 Lokalizowanie przewod w 2 Lokalizowanie belek 3 Lokalizowanie...

Отзывы: