
2 sec
1.
3.
–
+
–
+
4.
5.
2.
The wet/dry LED indicator is programmed in line with the relevant material characteristics so the LEDs also
provide information about whether the material should be classi
Ö
ed as dry, moist or wet.
However the values in index mode, which is independent of the material type, are output on a neutral scale
whose value increases as the moisture level rises. The LED indicator can be speci
Ö
cally programmed for index
mode by de
Ö
ning the end values for “dry” and “wet”. The difference between the value set for “dry” and
that set for “wet” is converted and displayed by the 12 LEDs.
Hold the two arrow buttons down simultaneously to access the menu. Press the “MODE” button to set the
value for “dry” (Dry Limit). Press “MODE” again to set the value for “wet” (Wet Limit). Hold the “MODE”
button down for two seconds to exit the menu again.
Setting the wet/dry threshold values in index mode
13
The MAX value is the maximum measured
value within a single measurement. Press both
arrow buttons at the same time to reset the
MAX value to zero. Do make sure that the
rubber electrodes on the rear of the device do
not come into contact with the material being
measured or with your hands when you press
these buttons.
MAX value
12
The display can be toggled between measured
values and a bar graph by pressing the arrow
buttons. The bar moves from left to right as
the moisture level increases. The maximum
value is also calculated. The arrow buttons can
be used to switch back to the measured value
display at any time.
Bar graph display
11
12
GB
Содержание MoistureMaster
Страница 134: ...134 134 ...
Страница 135: ...MoistureMaster 135 135 ...