12
Important notices
–
The laser points to the location that will be measured.
No objects may get into the laser‘s line of measurement.
–
The device compensates the measurement for different room
temperatures. Therefore allow the device a brief adaptation period
when changing locations with large temperature differences.
–
The device is only conditionally useable in outdoor areas and cannot
be used in strong sunlight.
–
The measurement results of outdoor measurements may be influenced
or falsified by rain, fog and snow.
–
In unfavourable conditions, e.g. with poorly reflecting surfaces, the
maximum deviation may be greater than 3 mm.
–
Carpeting, upholstery or curtains will not reflect the laser optimally.
Measure to flat surfaces.
–
Measurements made through glass (window panes) can falsify
measurement results.
–
An energy-saving function switches the device off automatically.
–
Clean with a soft cloth. Water may not be allowed to penetrate
the housing.
Error codes:
Err101:
Err104:
Err152:
Err153:
Err154:
Err155:
Err156:
Err157:
Err160:
Replace the battery
Calculation error
Temperature is too high: > 40°C
Temperature is too low: < 0°C
Outside the measuring range
Received signal too weak
Received signal too strong
Incorrect measurement or background is too bright
The device is moving too much to measure.
3 sec
View stored values
or
Memory function:
EN
2x
1x
3x
3 sec
1 sec
Min/max continuous measurement:
D
evice on
Press for 3 seconds
S
top
then release button
The LC display shows the max value, the min value and the current value.