06
1. Place the unit with its measuring edge (17) down on a straight surface and mark the
positions of the unit‘s ends on the underlying surface (see Fig. below). Switch the unit
on (4) and press the CAL button (3) until CAL 1 will appear in the display.
2. Press the CAL button (3) again. CAL 1 flashes. The display then
changes to CAL 2.
3. Now turn the unit around vertically by 180° such that its ends are positioned opposite
where they previously were but again exactly at the underlying surface marks (reverse
measurement). Again press the CAL button (3). CAL 2 flashes. Calibration is concluded
when the measured value appears on the display.
Calibration
4
Selection of unit of measurement
Button (5) allows the desired unit of measurement to be selected (° degrees, %, mm/m).
3
The unit is properly calibrated when it displays the same measurement value, i.e. the
underlying surface‘s deviation from absolute level, in both positions (0° and 180°).
!
Changing the angle reference value
With button (2), it is possible to transfer angles elsewhere. To do so, set the device to
the desired slope and press button (2). The display then changes to „0.0°“, „REF“ flashes
on the display and the required reference angle is set. The slope can now be transferred
to other objects.
Press button (2) again to deactivate the angle reference.
°C / °F / measured value
The ambient temperature is shown in °C and °F by briefly pressing the CAL button (3).
Press again to switch back to the measured value.
HOLD
Press the HOLD button (5) to hold the current measured value on the display.
Acoustic signal
The acoustic signal can be switched on or off with button (6). When the angle of slope
stands at 0°, 45°, 90° or the most recently stored value, this is indicated by an acoustic
signal.
When working with a changed angle reference value, the acoustic signal
is activated on reaching the new reference value (0°, 45°, 90° display).
!
The angle reference is not deactivated by switching off the device.
!
5
6
7
8
EN
1
Inserting batteries
Open the battery compartment and
insert batteries according to the symbols.
Be sure to pay attention to polarity.
1
Switching on and measuring
The DigiLevel Plus can measure angles continuously to 360°.
– Switch the DigiLevel Plus on using the on/off switch (4).
– The slope angle is shown in the display (8). If slopes are measured overhead,
the direction of display adjusts automatically.
– The current slope direction is also shown by the symbol (7).
Make sure that the reference function is deactivated before measuring.
!
2