7
ALARM TRIGGER SIGNALLING
FLASH CODES
If an alarm condition was generated whilst the system was armed, when the system is
disarmed the direction indicator lights will flash briefly (½ second) and an audible tone
(excludable) will be produced to indicate that an alarm condition has occurred. For 30
seconds after the system is disarmed and the ignition key is OFF, you can check the alarm
memory by looking at the LED installed on the motorcycle, you can determine which
sensor generated the last alarm condition. The LED will begin flashing and the repeated
sequence of flashes will identify the relative sensor:
Note:
Turning the ignition key ON or rearming the alarm system will reset the flash code
memory and the LED, will extinguish.
VERY IMPORTANT
·
When the ignition key is ON, it is not possible to arm the alarm.
·
In an alarm condition, the siren sounds for 30 seconds. At the end of this period the system
will stop sounding completely or pause for 5 seconds if a sensor is still detecting.
·
All sensors have a limit of 10 consecutive alarm cycles (In line with existing and proposed
European Noise Abatement Regulations).
LED Off:
No alarm condition occurred.
1 Flash/Pause:
Alarm condition generated by INCLINATION sensor.
2 Flashes/Pause:
Alarm condition generated by SEAT/SIDE PANEL/SIDE STAND sensor.
3 Flashes/Pause:
Alarm condition generated by IGNITION SWITCH sensor.
4 Flashes/Pause:
Alarm condition generated by POWER SUPPLY sensor.
5 Flashes/Pause:
Alarm condition generated by INFRA-RED/CONTACT GARAGE sensor.
FLASH CODES ALARM CONDITION GENERATED BY