Multifunction Switches (S1[7-8], S2[1-8])
If
RemoteControl=OFF
S1[7]
–
N/A
S1[8] - S2[1-8] – RS-232 configuration switches
If
RemoteControl=ON
S1[7-8] - S2[1-8] – Station address for remote management
S1[7] – A9 … S2[8] – A0
HWControl
: RTS/CTS flow control
OFF – Flow control disabled
*
ON – Flow control enabled
Baud1, Baud2, Baud3
: RS-232 baud rate
0 0 0 300 Baud
0 0 1 600 Baud
0 1 0 1200 Baud
0 1 1 2400 Baud
1 0 0 4800 Baud
1 0 1 9600 Baud
*
1 1 0 19200 Baud
1 1 1 38400 Baud
Parity
: parity handling on the RS-232 line
OFF – Parity checking and parity bit generation is disabled
*
ON – Parity checking and parity bit generation is enabled
ParOdd
: Parity selection
OFF – Odd Parity
*
ON – Even Parity
BCP1, BCP2
: Character length
0 0 5 bits / character
0 1 6 bits / character
1 0 7 bits / character
1 1 8 bits / character
*
StopBit
: Number of stop bits
OFF – 1 stop bit (in case of 5 bits/character 1,5 stop bit)
*
ON – 2 stop bits