Recommended protective distance between portable and mobile HF-

telecommunication devices and the  laser device without life supporting function 

 

Recommended protective distance between portable and mobile HF-telecommunication devices and the  
laser device 

The laser device is designed for the operation in electromagnetic ambient conditions where HF-disturbance 
variables are controlled. Client or user of the laser device can help to avoid electromagnetic disturbances by 
keeping the minimum distance between portable and mobile HF-telecommunication devices (transmitters) and the 
laser device as indicated below, dependent on the power output of the communication device. 

Power rating of the 
transmitter 

Protective distance dependent on the  transmitting frequency 

150 kHz up to 80 MHz 
d = 1,2 

 P 

80 MHz up to 800 MHz 
d = 1,2 

 P 

800 MHz up to 2,5 GHz 
d = 2,3 

 P 

0,01 

0,12 0,12 0,23 

0,1 

0,38 0,38 0,73 

1,2 1,2 2,3 

10 

3,8 3,8 7,3 

100 12 

12 

23 

If the maximum power rating for certain transmitters is not given in the above table the recommended protective 
distance d in metres (m) can be determined by using the equation indicated in the respective column, where P is 
the maximum power rating of the transmitter in Watt (W) according to the manufacturer of the transmitter. 
Note 1  At 80 MHz and 800 MHz  the higher frequency range is applied  
Note 2  These guidelines are not applicable in all cases. The propagation of electromagnetic quantities is 
influenced by the absorption and reflection of buildings, items and human beings. 

 

Содержание AS 50

Страница 1: ...AS 50 V 1 2 26 11 2009 1 AS 50 Cl 2M Instructions for Use ...

Страница 2: ...8 6 2 Technical data of the laser diodes depending on the model 9 6 3 Contents of delivery 9 7 Connectors and functional components 10 7 1 Indicators LED Display 10 8 Starting and using the device 11 8 1 Releasing the laser beam 20 seconds energy timer 11 8 2 Control displays 12 8 3 Laser indicator lamp 12 8 4 Power control 12 8 5 Audible indicator 12 9 Charging the battery 13 10 Charging the batt...

Страница 3: ...nes and manufacturer s declaration Electromagnetic immunity 17 12 5 Guidelines and manufacturer s declaration Electromagnetic immunity for the laser device without life supporting function 18 12 6 Recommended protective distance between portable and mobile HF telecommunication devices and the laser device without life supporting function 19 13 Manufacturer 20 14 Distributor 20 ...

Страница 4: ...clusion of liability The AS 50 should only be used for the purpose described in these operating instructions The manufacturer will not be liable for any damage or injuries resulting from usage not contained in these operating instructions The manufacturer reserves the right to make modifications in keeping with technological advances 1 2 AS 50 standard The AS 50 meets or exceeds the requirements o...

Страница 5: ...n standard 60601 1 The device meets the requirements EN 60825 1 Attention Observe the instructions in the manual for safe and effective usage of this device Symbol for the laser beam Warning for laser beam Aiming of laser beam must be adhered to avoiding any other part of the body other than the treatment area follow treatment protocol of this manual AS 50 Carry case Caution Explanatory Label Symb...

Страница 6: ...look directly into the laser beam outlet Laser radiation can cause eye damage Do not look directly into the beam or with optical instruments 4 2 Safeguarding against unauthorized usage To safeguard against unauthorized usage the AS 50 is equipped with a removable safety plug The laser can only be operated when the safety plug is inserted If the AS 50 is not being used store it separately to preven...

Страница 7: ...s a laser device which is to be used with 4 mm applicator and exclusively in anti smoking and wellness offices and should only be operated under constant supervision In order to apply the laser position the probe tip above the irradiation area 5 2 Indication for use Illumination of smaller spots and surfaces ...

Страница 8: ...10 Hz and cw Current supply charger Model FRIWO FW 7555M 05 5 V Weight main unit 0 2 kg Weight charger 0 5 kg Dimension main unit L x W x H 15 cm x 3 cm x 3 cm Dimension charger L x W x H 7 cm x 5 cm x 4 cm Operating conditions Room temperature 10 C to 30 C Relative humidity 30 to 75 Atmospheric pressure 700 hPa to 1060 hPa Transport and storage Room temperature 20 C to 40 C Relative humidity 30 t...

Страница 9: ... rad Safety distance NOHD Distance at which the radiation intensity or the radiation is equivalent to the limiting value of the maximum permitted radiation of the cornea MZB For more information please refer to the device plate 6 3 Contents of delivery AS 50 main unit with 4 mm applicator 1 key coding bridge charger Ansmann ASC 110 Traveller instruction manual carry case ...

Страница 10: ...sing the Start button to warn you of the ensuing laser radiation and then it is on continuous to glow L4 red on Will glow after pressing the ON OFF to inform you that the laser is READY L5 yellow on Will glow if the power is out of range Laser aperture Pilot beam Laser Start Stop 10 Hz 20 seconds energy timer ON OFF switch Indicator L3 Laser Indicator L5 Laser out of range Indicator L4 Laser ON So...

Страница 11: ...installing the batteries Replace the battery cover 8 1 Releasing the laser beam 20 seconds energy timer 1 Press one of the Start button The Pilot L1 L2 will indicate the beam direction The READY LED L4 will light continuously thereafter a Pressing button Start cw and will run on continuous mode for 40 60 seconds energy timer supply of 2 Joule at 50 mW b Pressing Start 10 Hz and will run on 10 Hz f...

Страница 12: ...he laser outlet indicates the direction of the invisible laser beam pilot beam The pilot beam meets the laser beam 20 mm away from the laser outlet The lamps L4 indicate if the AS 50 is READY The lamps L3 indicate if the AS 50 is operating 8 4 Power control The output is adjusted for value selection once the laser has been switched on The output is indicated L3 L5 will glow when the power has not ...

Страница 13: ...be charged For charging insert the plug of the charger into the socket on the back side of the AS 50 and connect it with the mains supply The batteries can be charged at any time because they do not have a memory effect LED indicators on the charger Power mains current red continuous Charge is connected to the mains supply Charge red continuous Accumulators will be charged Ready green flashing Cha...

Страница 14: ...AS 50 V 1 2 26 11 2009 14 10 1 Charger Ansmann ACS 110 Traveller ...

Страница 15: ...aintenance devices must be sent directly to REIMERS JANSSEN GmbH Medical Laser Technology Frohnacker 8 79297 Winden Germany Tel 49 7682 6558 Fax 49 7682 6640 service rj laser com www rj laser com Quality management according to EN ISO 13485 2003 11 2 Cleaning Disinfecting Please observe that cleaners for plastics soap are used for periodic cleaning of the plastic parts No penetrative or corrosive ...

Страница 16: ...sting and recalibration The producer will supply spare parts up to 10 years after delivery date 11 4 Disposal Due to the hazards of laser beams the AS 50 is not to be disposed of as standard electronic scrap The device is to be delivered to either the supplier or to the manufacturer for proper disposal 11 5 Warranty There is a 2 years warranty from the manufacturer The manufacturer guarantees oper...

Страница 17: ...all kinds of buildings including residential buildings and those directly connected to mains for the public supply which are also servicing buildings used for residential purposes Radiation of harmonic oscillation according to EC 61000 3 2 Conforms Radiation of voltage variations Flicker effect according to IEC 61000 3 3 Not applicable 12 4 Guidelines and manufacturer s declaration Electromagnetic...

Страница 18: ...ating of the transmitter in Watt W according to data from the manufacturer of the transmitter and as recommended protective distance in meter m According to a local a investigation the field intensity for all frequencies of immobile radio transmitters should be less than the conformity level b Interference is possible in the surroundings of devices carrying the following signs Note 1 At 80 MHz and...

Страница 19: ... of the communication device Power rating of the transmitter W Protective distance dependent on the transmitting frequency m 150 kHz up to 80 MHz d 1 2 P 80 MHz up to 800 MHz d 1 2 P 800 MHz up to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 If the maximum power rating for certain transmitters is not given in the above table the recommended prote...

Страница 20: ...6640 service rj laser com www rj laser com Quality management according to EN ISO 13485 2003 14 Distributor Alexander Müller General Manager Facilitas Healthcare Centroallee 263a 46047 Oberhausen phone 49 0 208 88 22 74 95 Fax 49 0 208 88 22 74 96 Mobil 49 0 179 11 00 675 a mueller facilitas de www facilitas de www jetztaufhoeren de www lipovanish de ...

Отзывы: