![Laser 6205 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/laser/6205/6205_manual_3781320004.webp)
Instructions
Refer to
Controls
diagram on page 3.
How to select the unit measurement scale:
1. Press
Memory
(
J
) and
Peak/Trace
(
I
) buttons together.
2. Release to select different torque measurement scales (Nm | ft/lb | in/lb | Kg/m).
3. The unit value will automatically change when the measurement scale is selected.
How to select torque settings and use the torque wrench:
1. Select and hold the
+ button
(
G
) and/or the
- button
(
H
) until the required torque
figure is reached.
2. The target will display (flashing) for 10 seconds then revert to 0.0.
3. To reduce the setting continue to press and hold the
+ button
(
G
) until it goes past
the maximum setting (for example, 100Nm, 73.8lb/ft), then set to the required torque
figure.
4. Slowly and steadily apply torque to the fastener.
5. The LEDs (
E
) will flash and an intermittent warning beeper will sound when you are
20% away from the target torque.
6. When full torque is reached the LEDs will stop flashing (stay on) and a constant tone
will be heard.
7. The required torque figure has been reached so do not apply further torque.
8. Tighten in a slow and controlled manner and stop applying pressure immediately
the torque wrench indicates the required setting has been reached.
Tightening too
quickly will result in an inaccurate final torque figure.
How to set peak and trace modes:
1. Press and release the
Peak/Trace
button (
I
) (with the wrench turned
On
).
2. The display will show
PtoP
(Peak)* or
trACE
(Trace)*.
3. The display will revert to 0.0 after 2 seconds.
4. * —
Peak
display stays at highest torque setting reached;
Trace
display follows
torque setting being applied, then returns to 0.
Memory:
1. Turn the wrench On with On/Off button (
F
).
2. Press the
Memory
button (
J
) and release.
3. The display will show the memory number
P01
then the torque setting for that
memory position.
4. Press Memory button again for the next memory pre-set position.
5. The memory settings show the last torque figures set manually by the user. The
display
P01
is the latest setting,
P50
would be the oldest setting.
4
Содержание 6205
Страница 7: ...NOTES 7...