Laser Technology, Inc. TruPulse L2 User’s Manual 1st Edition
Section 4 - Basic Operations
Page 11
Copyright© 2023, Laser Technology, Inc. All rights reserved.
Firmware Revision Number
The firmware revision number provides Laser Tech Service Department information
about your TruPulse L2. To display the firmware revision.
1. Start with the TruPulse L2 powered OFF, press-and-hold FIRE button.
•
While fire button is held down, press the Disp/MENU button.
•
Press the Down Arrow.
2. Looking through the eyepiece the firmware version will be displayed
In Figure 9, F-06.0 is used as an example.
3. Release the FIRE button to start normal operation.
Factory Reset
It is possible to restore the TruPulse L2 factory default settings.
Restoring the default settings affects some of the system setup options.
1. Start with the TruPulse L2 powered OFF, press-and-hold fire button.
•
While fire button is held down, press the Disp/MENU button.
•
Press the Up Arrow.
2. The Display will change to “red” indicating the settings have been reset.
3. Release the FIRE button to start normal operation.
Factory Reset Workflow
Factory Default Settings
Units of Measurement:
•
Distance:Meters (M)
•
Inclination: Degrees (°)
Targeting Mode:
Standard (STD)
Reticle Options:
Full
Pulse:
Off
Measurement Mode:
Horizontal Distance
Figure 9