PLMNL0243 REV. A, Effective Date: 03/24/16
26
FiberMINI ™ 2.0 Operation Manual
5. Take the cover glass holder to a clean
area.
6. Remove the cover glass from the
holder by applying pressure with your
fingers to the surface of the cover
glass, opposite the seal.
The seal and cover glass will pop
out.
Save the seal.
Figure 35
The cover glass holder orientation
notch and each component MUST
match
7. Install the cleaned (according to
) or new cover glass by
placing it into the holder.
8. Press the seal ring into the holder to
retain the cover slide.
The seal is bi-directional, so it
can be inserted in either
direction.
Replace the existing seal with a
new one if it appears damaged.
9. Open the cover glass door.
10. Reinsert the cover glass holder into
the head.
11. Close the cover glass door.
5.4 Servicing the Tip Retainer
Assembly
Before opening any part of the
head, clean off the dust and/or
process debris using an exterior
cleaning towel (PLTLS0023) or
equivalent.
5.4.1 Heads with Height Sensing
1. Unthread the tip wire
(PLTTW0003) from the tip
retainer assembly. See
Figure 36