Instruction Manual 

Modular Hand Pump “WI040” 

 

 

4. START UP 

 

 

This is a modular pump, it is supplied with a lever to pump the oil and its use is very simple. 

 

These pumps are lightweight, easy to fix by the base so, we can use them with different sizes of tanks. 

 

To start operating with the pump, we only have to place the lever in the upper of the pump and pump several times until reach the wished stroke of the hydraulic 
element in the system. 

 

CYLINDER-HAND PUMP INSTRUCTIONS 

 

Unpack and visually check all the components, making sure that there are no oil leaks, loose or damaged plugs, damaged threads, etc. Never use components 
that are damaged or appear to be in poor condition.  

 

Assemble the device in accordance with the instructions given in the diagram, first checking that you have all the necessary material. 

 

Check the correct installation and perfect functioning of the device with a load, in accordance with the procedure outlined below: 

 

SINGLE ACTION INSTALLATION 

 

Release the pump drive lever by removing the hook from the lever-holder housing.  

 

Pump manually with the drive screw open (rotate a few times to loosen) in order to fill the pump’s internal circuit with oil.  

 

Close the drive screw by turning clockwise manually. You do not need to close too tightly. 

 

Now pump using the drive lever. First, fill the hose with oil. The number of thrusts required will depend on the length of the hose and the flow supplied by the 
pump piston. With single-speed pumps, the flow will remain the same at all times, regardless of the load or pressure. With two-speed pumps, the large piston 
will  be  activated  during  the  load-free  feed  movement,  and  when  the  device  comes  into  contact  with  the  load,  an  internal  large  piston  relief  value  will  be 
automatically triggered and only the oil supplied by the small piston will be available up to 700 kg/cm”, which is the maximum pressure for the device.  

 

Once the hose is full of oil, the cylinder piston will start to advance.  

 

If the cylinder has a mechanical limit switch capable of withstanding the maximum device pressure, continue pumping until the limit switch is reached.  

 

If any control elements (pressure gauges) are available, you will be able to see how the pressure increases along with the effort required moving the lever.  

 

Keep pumping until you obtain the maximum pressure (700 kg/cm”). In this way you will be able to check the correct functioning of the internal safety valve 
and the absence of oil leaks in the installation.  

 

Maintain pressure in the installation for a short period of time (1 minute) without pumping, in order to check the correct functioning of the pump’s check valve.  

 

Gently open the pump’s drive screw (by turning anticlockwise) in order to protect the fall of the pressure gauge needle. Do not force the drive screw open. The 
cylinder will not move back more quickly because the screw is looser. A couple of turns will be sufficient.  

 

If the cylinder has a return spring (SM, SMP, SMX, SH, TE, T, SMA, SHA, CY, KC) the piston will move back automatically. The  return speed may be slow 
in some applications. In this case, we recommend the use of double effect cylinders. In the case of load return cylinders(SP,SX,SL,SS,ST,STX), you will need 
to push the piston back using more or less force, depending on the size and position of the cylinder. 

 

In cylinders without a mechanical limit switch (SS, ST, STX) this type of test cannot be carried out. If you do not have a test bench, you will have to test the 
installation  using  the  actual  load  in  the  application.  This  operation  should  be  carried  out  with  extreme  care  by  experienced  personnel  and  maximum  safety 
measures should be applied.  

 

Repeat the process as many times as necessary until you are comfortable handling the device. 

 

If using close or check valves, or  working with various cylinders via flow distributors, remember to take into consideration  the effect these accessories may 
have on the functioning of the device, and establish an operating procedure in order to avoid unwanted effects.  

 

DOUBLE ACTION INSTALLATION 

 

The connection of the quick plugs is, if possible, even more important here, since a bad connection  will not only prevent the device from functioning, it may 
also generate excessive pressure build-up that may cause the cylinder to break. Take note of which hose connects to the thrust chamber and which to the return 
chamber. 

 

All double action LARZEP cylinders are equipped with a mechanical limit switch capable of withstanding the nominal pressure. You can therefore carry out 
the test described in the previous section. If you are working with another type of cylinder and are not 100% sure, do not carry out this test. 

 

Release the pump drive lever by removing the hook from the lever-holder housing. 

 

Turn the control of the distributing valve to the central position and pump and few times to fill the internal channels with oil.  

 

Turn the lever to one side and pump. Oil will flow through the hose connected to the side to which the valve lever is rotated. If this hose is connected to the 
cylinder’s thrust chamber, the piston will move forward. The oil in the return chamber will  flow freely through the other hose to the pump tank. Until the 
moment the cylinder connects with the load, flow is supplied by both the large and small pistons. 

 

Continue pumping until you reach the limit switch. At this moment an internal large piston relief value will be triggered, and only the oil supplied by the small 
piston will be available. Subject the installation to pressure to check for leaks.  

 

Stop pumping and check (preferably using a pressure gauge) that the installation maintains the pressure level.  

 

Turn the valve lever to the other side and pump. Oil will flow to the return chamber and the piston will move  back. The oil in the thrust chamber will flow 
freely back to the tank.  

 

Repeat the process as many times as necessary until you are comfortable handling the device. 

 

If using close or check valves, or  working with various cylinders via flow distributors, remember to take into consideration the effect  these accessories may 
have on the functioning of the device, and establish an operating procedure in order to avoid unwanted effects. 

 

5. MAINTENANCE.

 

Checking the oil level. 

 

With the pump in vertical position (base downwards), unscrew or pry off the plug. Check the level on the dip stick. 

 

This check must be carried out with the cylinder fully retracted. Excessive amount of oil in the tank will lead to internal pressures which will hamper the 
function of the pump. 

 

Filter the oil before filling up the pump. 

 

Once the equipment is being used the areas exposed to wear and oxidation must be cleaned and greased. 

BREAK DOWNS AND 

REPARATIONS

 

THE CYLINDER DOESN´T AVANCE 

 

Lack of oil in the tank ____ 

Check the oil.

 

 

Couplers not fully inserted ____ 

Check couplers.

 

 

Admission  ball  valve  failure  (19)  ____ 

Clean  the  seat  and 

replace the ball. 

 

Closing  ball  valve  failure  (22)  ____ 

Clean  the  seat  and 

replace the ball. 

 

THE CYLINDER DOESN´T REACH WORKING PRESSURE

.

 

 

Relief valve decalibrated (12) ____ 

Calibrate the valve. 

 

Retention ball valve failure (20) ____ 

Clean the seat and replace the ball. 

 

Closing ball valve failure (22) ____ 

Clean the seat and replace the ball. 

 

Pressure seal damaged (26) ____ 

Replace the seal.

 

 

Cylinder pressure seal damaged (see cylinder) ____ 

Replace the seal.

 

 

 

THE CYLINDER DOES NOT RETRACT

 

 

Too much oil in the tank ____ 

Check the level. 

 

 