background image

1706K21A 

 

Page 1 of 26 

 

Introduction to the DR-119

 

The DR-119 display is presented as an easy-to use clock adjusted and calibrated at factory. The main 

window shows the current time in HH:MM format. The main window can be set to turn on and turn  off at the 
time set by user  and  is adjustable in brightness (see  “Parameters” in this manual). In all cases, the display 
never  turns  off.  There  are  add-on  functions  depending  on  the  display.  These  functions  are  fully  compatible 
and can be combined with each other: 

If the display includes option A, it has an integrated GPS. The antenna contents a magnet that permit 

to  fix  it  to  a  magnetic  surface.  The  first  time  the  display  is  turn  on,  the  quality  of  the  GPS  signal  must  be 
verified some minutes after the power-

up. This is done using one of the parameters of the display (see “GPS 

option

in this manual).  

If the display includes option NE (Ethernet connectivity), this display hosts a web site where the user 

can see the status of the display and configure it. This function allows the display to be used as a server for 
other displays to synchronize the hour through the Ethernet, as well as updating its time and date through a 
SNTP  server.  User  can  configure  and  request  the  time  through  TCP/IP  commands.  The  default  IP  is 
192.165.1.100. 

See “Ethernet option” in this manual for more information. 

If  the  display  includes  option  X  (RS-485  connectivity),  this  display  can  be  configured  as  a  RS.485 

server/client. This means that the display can connect  with  other displays to sync between  them, as well as 

the  user  communication  through  commands.  If  the  display  also  includes  the  GPS  or  Ethernet  option,  the 
display can work as a bridge between both options. See “RS-485 option” for more information  

 

 

TECHNICAL MANUAL DR-119 

Clock with GPS, Ethernet and RS-485 functions 

Содержание DR-119

Страница 1: ...of the display see GPS option in this manual If the display includes option NE Ethernet connectivity this display hosts a web site where the user can see the status of the display and configure it Thi...

Страница 2: ...47 to 63 Hz Consumption 35VA Consumption at minimum brightness 13 2VA Display 4 digits 7segments 100mm height two central dots Red LED Visibility 50 meters Environmental conditions Operating temperatu...

Страница 3: ...digit corresponding to the units of the minute If the time has changed the seconds are changed to 0 when leaving the menu Take in consideration that the time displayed in the menu must be UTC time In...

Страница 4: ...control of brightness depending on the room light 1 Manual control of brightness Fixed brightness depending on the right digit Right digit Brightness level The functionality of this digit depends on t...

Страница 5: ...ode Baud Rate Data bits Parity Stop bits 01 4800 Bauds 7 bits No parity 1 02 9600 Bauds 7 bits No parity 1 03 19200 Bauds 7 bits No parity 1 04 4800 Bauds 8 bits No parity 1 05 9600 Bauds 8 bits No pa...

Страница 6: ...Parameter J Maintenance parameter This parameter is used in factory and must not be modified Parameter P Exit menu Press Advance key to leave menu GPS option Displays that include GPS sync with the G...

Страница 7: ...or the default IP of the display is out of the IP range of you LAN it is recommended to use the PC program Display Discoverer downloadable from the web www lartet com In this program the displays conn...

Страница 8: ...1706K21A Page 8 of 26 Tip the new IP and click OK There will appear a message in the main window with the message sent to the display...

Страница 9: ...1706K21A Page 9 of 26 After some seconds click the Refresh button The display appears with the new IP Click the display IP to open a new tab in the browser The main page of the web server is shown...

Страница 10: ...splay which usually is in a difficult access point The web page can be accessed remotely if the router is correctly redirected See Annex 2 View the web page remotely for more information The main page...

Страница 11: ...in the field The second tab allows configuring the network parameters of the display including the IP address DNS etc The display can use DHCP to get these parameters on its own The name of the displ...

Страница 12: ...ly When clicking the button validate the system saves the changes and reboots If the parameters are put manually the work is finished On the other side the display may have changed the IP address This...

Страница 13: ...tions parameters seen from the webpage the user must configure Other parameters don t care Networks with one display One display Ethernet network Ethernet network Configure net parameters Sync no Time...

Страница 14: ...oth are configured the same way Ethernet network Ethernet network Ethernet network Ethernet network Configure net parameters Sync SNTP Write the server addres in the field SNTP server Configure net pa...

Страница 15: ...others sync with the server display Ethernet network Ethernet network Client display Configure net parameters Sync Display Ethernet Write the display server addres in the field Client display Configur...

Страница 16: ...TP server and serves the time to the other displays Ethernet network Ethernet network Client display Configure net parameters Sync Display Ethernet Write the display server addres in the field Client...

Страница 17: ...er o a cloud SNTP server All displays update from the SNTP server specified Ethernet network Ethernet network Configure net parameters Sync SNTP Write the server addres in the field Configure net para...

Страница 18: ...Frame This frame only includes the code This does not send any data Code End of block ACII P H Hexa 50h 48h Response frame Code Data End of block Code Day Month Year Space Hour Minute Second End of bl...

Страница 19: ...ion must be the same for all RS 485 network There are many configurations possible only with RS 485 or combining different options this displays offer The following networks are the most usual but the...

Страница 20: ...21A Page 20 of 26 Sync through a display with GPS RS 485 network RS 485 network Client display Sync Parameter 4 2 3 RS 485 Client display Sync Parameter 4 2 3 RS 485 Server display Sync Parameter 4 2...

Страница 21: ...d to a SNTP server Ethernet network Ethernet network RS 485 network RS 485 network Client display Sync Parameter 4 2 3 RS 485 Client display Sync Parameter 4 2 3 RS 485 Server display Configure net pa...

Страница 22: ...Display time request P H Time programming F H Display time request Frame This frame only includes the code This does not send any data Code Address End of block ACII P H H L Hexa 50h 48h Example Requ...

Страница 23: ...nd End of block ASCII F H H L DD MM AA HH MM SS Hexa 46h 48h 20h Example Send 13 16 00 16 05 2013 to the display at address 03 Code Address Data End of block Code Address Day Month Year Space Hour Min...

Страница 24: ...nal Port The same port as the start port Internal Start Port The port the user enters wants to enter the display In this case the port is 80 which is the standard web page access IP address The LAN IP...

Страница 25: ...le responsibility that the aforementioned product complies with the following European directives Directive LVD 2006 95 CEE Low Voltage Directive Standard UNE EN61010 1 Security in electric equipment...

Отзывы: