![Larson Electronics WAL-QP-4XWP60E-25-1227 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/larson-electronics/wal-qp-4xwp60e-25-1227/wal-qp-4xwp60e-25-1227_instruction-manual_3782488002.webp)
WAL-QP-4XWP60E-25-1227
Larson Electronics, LLC
Phone: (800) 369-6671
Fax: (903) 498-3364
www.larsonelectronics.com
2
of
3
EXTENDING
1.
Loosen hand screw for extending the light head. Once loose, extend light head until desired
height is achieved with at least 1ft - 2ft remaining inside pole for support.
WARNING:
DO NOT over extend light head completely allowing extension pole to free from base! If
the light head becomes free, serious injury or death can occur. Larson Electronics shall not be held
liable for injuries caused by misuse.
2.
When desired height is achieved, tighten hand screw to secure light head.
LOWERING
1.
To lower mast, grasp light head and slowly loosen hand screw. Lower the light head and
tighten hand screw.
WARNING: DO NOT loosen hand screw allowing light head to fall freely. This can damage the unit
and cause serious injury or death. Always grasp light head before lowering. Larson Electronics shall
not be held liable for injuries caused by misuse.
The tripod mount light tower can be disassembled for storage or transporting. Unplug light from power
source and remove light head following previous steps for attaching.
Once the light head has been removed, loosen hand screw for legs and fold them up. Wheel to
desired location or remove from wheel base for complete disassembly.
THE LENS AND CORD MUST BE ROUTINELY CHECKED FOR CUTS, BREAKS, SCRATCHES OR ANY
SEVERE ABRASIONS, AND IF ANY ARE FOUND, THE PARTS MUST BE REPLACED BEFORE
RESUMING USE OF THE LIGHT TOWER.
WIRING
(see attached wiring diagram)
This unit comes preconfigured with
25 feet SOOW Cord and your chosen configuration of cord cap.
Once deployed, plug cord cap into compatible receptacle with
Voltage: 120/277 VAC 50/60Hz
WARNING:
CHECK NAMEPLATE
FOR PROPER VOLTAGE. DAMAGE
FROM IMPROPER VOLTAGE WILL
VOID WARRANTY.