Attach supply line wires to the appropriate light fixture wires as shown 

in the diagram 

 

Secure  each  pair  of  wires  according  to  the  diagram.  Utilize  a  junction  box  or 

similar  device  and  take  precautionary  steps  for  weatherproofing  all 

connections if installed in a location where water may come in contact with the 

unit. Ensure the unit is properly grounded and that wiring is done according to 

all local and national electrical/building codes. 

Standard Cord Cap 

This  unit  comes  pre-wired  from  factory  with  the  selected  cord  cap.  Take 

precautionary  steps  for  weatherproofing  all  connections  if  installed  in  a 

location  where  water  may  come  in  contact  with  the  unit.  All  outdoor 

installations  and  indoor  installations  near  a  wet  location  require  the  use  of  a 

GFCI  device  for  safety,  according  to  the  National  Electrical  Code® 

(NEC). Ensure the unit is properly grounded. 

OPERATION

Surrounding "dirty" air is drawn into the UV sanitation unit via a ventilation fan. The "dirty" air passes through the UV 

sanitation chamber where it is treated with UVC light using powerful fluorescent lamps. The disinfection process kills up to 

99.9% of viruses, bacteria, mold, spores and other harmful microbes. Clean sanitized air exits the chamber through the 

bottom base, which is equipped with a vent and air filter, and is released into the environment. This low-maintenance air 

disinfection process is continuous.

1.

Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine

checks to be made on a yearly basis. Frequency of use and environment should determine this.  It is

recommended to follow an Electrical Preventive Maintenance Program as described in NFPA 70B:

Recommended practice for Electrical Equipment.

2.

The lens should be cleaned periodically as needed to ensure continued photometric performance.

Clean the lens with a damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid

cleaner.

3.

Inspect the cooling fins on the luminaire to ensure that they are free of any obstructions or

contamination (i.e. excessive dust build-up). Clean with a non-abrasive cloth if needed.

4.

Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.

MAINTENANCE 

Caution: 

To avoid personal injury, disconnect power to the light and allow the unit to cool down before 

performing maintenance. 

Warning: 

No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void 

the warranty. 

B

U

LB 

REP

L

A

C

EMENT

Warning:

 

Do not touch bulb with bare hands. The oils in your skin will damage the lamp. Fingerprints will result in reduced performance 

and  significantly  reduce  the  lifespan  of  the  lamp  unless  removed  with  alcohol.  Be  sure  fixture  is  disconnected  from  power  source  and 
cooled off before servicing.

To replace a bulb in your 

fixture

, you must first remove the 

light

 from power

Remove the cover from the fixture to reveal the bulbs. 

Remove 

the bulb to be replaced by grabbing the ends and pressing either up or down against one of the spring loaded bulb receptacles. This will 
free the other end and allow you to remove the bulb. Replace the bulb with one of the same type and rating. Install the new bulb by aligning 
the 2-pin connector with the slots in the bulb receptacle at the bottom. Press the bulb down against the spring loaded receptacle to create 
room at the top, and align the two top pins on the bulb with the top receptacle and release. Repeat this process for any remaining bulbs that 
need to be replaced. Test the new bulbs before reinstalling the 

fixture's cover

.

 After ensuring proper operation

,

 replace the lens cover and 

then

 

connect the fixture to power, and continue use.

  