Door Barrier Germicidal UV-C Fixture
(1) 30W UV-C Fluorescent Lamp - 36" Wide - Hospital Grade Stainless Steel
Instruction Manual
Thank you for your purchase of the Larson Electronics
I
IND-DBL-36-1L-R1-120V
Fluorescent Fixture.
IMPORTANT
READ
CAREFULLY
BEFORE INSTALLING THIS FIXTURE. SAVE THESE INSTRUCTIONS FOR FUTURE
REFERENCE.
THE
IND-DBL-36-1L-R1-120V
MUST
BE
WIRED
IN
ACCORDANCE
WITH
NATIONAL
ELECTRICAL
CODE AND ALL APPLICABLE LOCAL CODES. PROPER GROUNDING IS REQUIRED FOR SAFETY.
WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL, OPERATE AND MAINTAIN THIS
PRODUCT. IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT OF THIS INSTRUCTION
SHEET, CONSULT AN ELECTRICIAN. THERE ARE NO SERVICEABLE PARTS INSIDE.
WARNING:
MAKE SURE POWER IS TURNED
OFF
BEFORE STARTING THE
INSTALLATION OR PERFORMING ANY MAINTENANCE.
RISK OF FIRE/ELECTRIC SHOCK –
DISCONNECT POWER AT BREAKER BEFORE INSTALLING OR SERVICING.
RISK OF PERSONAL INJURY –
FIXTURE MAY BECOME UNSTABLE OR DAMAGED IF NOT INSTALLED PROPERLY.
RISK OF BURN –
ALLOW FIXTURE TO COOL BEFORE SERVICING.
WARNING:
ULTRAVIOLET LIGHT IS HARMFUL TO EYES AND SKIN. DO NOT STARE DIRECTLY INTO THE
ULTRAVIOLET BEAM WITHOUT WEARING PROTECTIVE GEAR TO PROTECT EYES FROM LONG TERM DAMAGE.
UNPLUG LAMP BEFORE SERVICING.
The IND-DBL-36-1L-R1-120V from Larson Electronics is a Door Barrier UV-C Fixture that projects a concentrated beam of
germicidal UV-C light into doorways from above. This beam provides a high-intensity dose of UV-C light to people passing
through the doorway. This brief exposure offers an additional layer of germ killing safety to anyone who walks through the
doorway above which the IND-DBL-36-1L-R1-120V is installed and helps to effectively control the airborne transmission of
microorganisms between areas. This hospital grade stainless steel door barrier germicidal fixture features a 30 watt UV
bulb that produces 10.77 watts of UV output at a wavelength of 254nm. The IND-DBL-36-1L-R1-120V is designed to be
mounted above a 36" wide doorway, operates on 120 V AC current, and is hard wired. Multiple units can be mounted in
tandem to cover wider doorways.
Mounting
The IND-DBL-36-1L-R1-120V is designed to be wall mounted.
Warning:
Check product label for correct input voltage!
Attach supply line wires to the appropriate light fixture wires as shown
in the diagram
Secure each pair of wires according to the diagram. Utilize a junction box or
similar device and take precautionary steps for weatherproofing all
connections if installed in a location where water may come in contact with the
unit. Ensure the unit is properly grounded and that wiring is done according to
all local and national electrical/building codes.