WIRING 

This unit is designed to operate on 12V DC. Link-up with the camera is achieved via customer provided standard stranded 

cable such as SOOW. The cable video/power drop cable can be routed either through the mounting surface or through a 

cable guide on the edge of the mounting base.

Standard pigtail(flying leads) wiring 

We strongly encourage a licensed electrician install this product

, in all locations especially in outdoor areas 

where weatherproofing may be required. Universal voltage driver permits operation at 1

2

V DC.

Warning: 

Check product label for correct input voltage!

 

Attach supply line wires to the appropriate light fixture wires as shown 

in the diagram 

 

Secure each pair of wires according to the diagram. Utilize a junction box or 

similar  device  and  take  precautionary  steps  for  weatherproofing  all 

connections if installed in a location where water may come in contact with the 

unit. Ensure the unit is properly grounded and that wiring is done according to 

all local and national electrical/building codes. 

Low Voltage DC 

Connect power to power supply outputting low voltage 

at 12

  Volts  DC. This variable voltage allows greater versatility 

without affecting light output. Ensure deutsch connectors are properly connected (If applicable)

.

 

MOUNTING

 

The EXPCMR-ALG-HDSD-1080P-12VDC explosion proof security camera is secured to flat surface, such as a ceiling or 

wall, using and adjustable reverse pedestal style bracket. The included mounting bracket allows 90° vertical adjustment and 

360° of swivel for precision aiming.

MAINTENANCE 

Caution: 

To avoid personal injury, disconnect power to the light and allow the unit to cool down before 

performing maintenance. 

Warning: 

No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void 

the warranty. 

1.

Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine

checks to be made on a yearly basis. Frequency of use and environment should determine this.  It is

recommended to follow an Electrical Preventive Maintenance Program as described in NFPA 70B:

Recommended practice for Electrical Equipment.

2.

The lens should be cleaned periodically as needed to ensure continued photometric performance.

Clean the lens with a damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid

cleaner.

3.

Inspect the cooling fins on the luminaire to ensure that they are free of any obstructions or

contamination (i.e. excessive dust build-up). Clean with a non-abrasive cloth if needed.

4.

Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.