MOUNTING

The EPS-PB10-MS-SPDT is compatible with surface mounting applications.

Mount the back box by means of mounting lugs. Install conduit nipple and sealing fittings, to be installed on 

each conduit entrance or exit to the enclosure back box in Class I and Class II areas. Thread conduit into 

sealing fitting (Note: For Class I areas, the conduit should engage [5] full threads.)

The conduit threads should be lubricated with a non-electrical insulating lubricant or pipe joint compound that 

will not promote corrosion or chemically attack aluminum.

After conduit system has been properly installed, pull the wires and make electrical connections as required. 

The electrical circuits and ground continuity should be checked with an instrument approved for the area. 

Notice: Connect only copper wire to this device.

All conduits entering or leaving the enclosure must be sealed within 18” of the enclosure with listed sealing 

fittings.

Caution must be taken during installation to be sure that the ground flange flame joints of the cover and box 

are not scratched, nicked, or damaged. Before assembly of the cover to the box, the mating ground surfaces 

of both the box and cover should be wiped clean to assure that the ground flame joint will be free of all 

foreign particles such as lint, dust or dirt.

After tightly bolting the cover assembly/assemblies to the enclosure, all box to cover flame joints should be 

checked with a 0.0015” thick feeler gauge such that the gauge will not enter the flame path more than 1/8” at 

any point.

INSTALLATION

MAINTENANCE 

There are no serviceable parts inside the fixture. However, it is good practice to routinely clean and check the 

fixture for proper function. 

All moving shafts should be lubricated occasionally to prevent binding. Only use a lubricant which is suitable 

for use with aluminum or stainless steel. If devices are to be installed in corrosive areas which will attack 

aluminum alloys containing less than 0.4% copper (boxes and covers) and 303 stainless steel (mostly 

shafts), the device should be suitably protected from the corrosive material. 

CAUTION:

 To prevent ignition of hazardous atmospheres, disconnect from the supply circuits before opening 

the enclosure; keep tightly closed while circuits are energized.  

Disconnect power running to the 

unit

 and be sure the fixture is cool to the touch.

Use a non-abrasive cleaning solution to clean the 

fixture

.

USE AND CARE

Unauthorized modification may impair the function and/or safety of this device and could affect the life of the equipment. 

Always check for damaged or worn out parts before using the device. Store it in a secure place out of the reach of 

children when not in use. Inspect for good working condition prior to storage and before re-use.

 

 

REPLACEMENT PARTS

The 

EPS-PB10-MS-SPDT

 is designed to provide years of reliable performance. Should the need for replacement parts 

arise, please contact Larson Electronics. 

THESE INSTRUCTIONS MAY  NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. 

SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT 

[email protected]

 OR BY PHONE AT 1-800-369-6671 FOR FURTHER ASSISTANCE. 

PLEASE VISIT LARSONELECTRONICS.COM FOR 

WARRANTY

 AND 

RETURN

 INFORMATION.

Отзывы: