background image

EPL-FL1524-25-1523

Larson Electronics, LLC

 

 Phone: (800) 369-6671 

Fax: (903) 498-3364 

www.larsonelectronics.com 

2

 of 

4

 

WARNING: 

USER SHOULD BE TRAINED IN THE PROPER USE AND MAINTENANCE OF THIS DEVICE. WHEN EXTENSION 

CORD IS CONNECTED TO A POWER SOURCE IN HAZARDOUS AREA, PLUG AND MATCHING RECEPTACLE 

MUST BE SUITABLE FOR HAZARDOUS LOCATION INVOLVED. IMPROPER USE OF THIS DEVICE, ASSOCIATED 

PLUG, RECEPTACLE, AND CORD CAN LEAD TO SERIOUS INJURIES OR DEATH TO PERSONNEL. 

PERIODIC INSPECTION OF THE RECEPTACLE AND CORD IS NECESSARY.

 

THE CORD MUST BE ROUTINELY CHECKED FOR CUTS, BREAKS, OR ANY SEVERE ABRASIONS, AND IF ANY 

ARE FOUND, THE CORD MUST BE REPLACED BEFORE RESUMING USE OF THE UNIT.  

ELECTRICAL POWER SUPPLY MUST BE “OFF” BEFORE AND DURING INSTALLATION AND MAINTENANCE. 

INSTALLATION AND MAINTENANCE PROCEDURE MUST BE PERFORMED BY A TRAINED AND COMPETENT 

ELECTRICIAN. 

IF ANY PARTS OF THE RECEPTACLE OR PLUG APPEAR TO BE MISSING, BROKEN, OR SHOW SIGNS OR 

DAMAGE, DISCONTINUE USE IMMEDIATELY. REPLACE WITH THE PROPER REPLACEMENT PART(S) BEFORE 

CONTINUING SERVICE. 

WIRING 

Warning: 

Check product label for correct input voltage!

 

Exp Cord Cap 

Position device near work area for operation. Run cable to  nearby  power 

source. Insert and twist-lock explosion-proof plug into a compatible receptacle 

within the hazardous environment. See 

plug operation

 below. 

PLUG OPERATION 

Electrical connection between plug and compatible receptacle is accomplished 

after plug fully inserts into receptacle and rotated clockwise. 

1.

Lift receptacle door and locate polarization on mating plug pin and

receptacle face. Insert plug straight all the way into receptacle until it

cannot go further.

2.

Rotate plug clockwise limit (37º), this closes internal contacts and

completes circuit. This also mechanically locks plug into receptacle so it

cannot be pulled out.

3.

To remove plug, push plug inward and turn to counterclockwise, pull plug

straight out.

The Larson Electronics EPL-FL1524-25-1523  Hazardous Area Fluorescent Work light is F.M. approved Class 1 Division1 Groups C and D 

and Class II Division 1 groups E, F and G. With a 2 foot long 15 watt fluorescent lamp, this hazardous location light provides a very wide 

flood beam which can be suitable for paint spray booth inspection or general portable lighting in confined spaces like fuel tanks or grain 

storage areas.

MAINTENANCE 

Caution: 

To avoid personal injury, disconnect power to the light and allow the unit to cool down before performing maintenance. 

Warning: 

No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void the warranty. 

1.

Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine

 

checks to be made on a 

yearly basis. Frequency of use and environment should determine this.  It is

 

recommended to follow an Electrical Preventive 

Maintenance Program as described in NFPA 70B:

 

Recommended practice for Electrical Equipment.

2.

The lens should be cleaned periodically as needed to ensure continued photometric performance.

 

Clean the lens with a 

damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid

 

cleaner.

3.

Inspect the cooling fins on the luminaire to ensure that they are free of any obstructions or

 

contamination (i.e. excessive 

dust build-up). Clean with a non-abrasive cloth if needed.

4.

Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.

Отзывы: