background image

 

Larson Electronics LLC     www.LarsonElectronics.com     [email protected]

 

9419 E US HWY 175, Kemp, TX 75143 - P: (800) 369-6671 - F: (903) 498-3364  

ASX-25 

 

When starting the flashlight for the first time (cold start), it is recommended that user allows 
HID to power up to full (40-60 seconds) before powering off again. This allows the lamp time to 
achieve a temperature hot enough to vaporize the additives and prevent deposits from forming 
on the inner arc chamber walls. When powering up, it is normal for the lamp to “flicker”, this is 
the result of the metal salts in the arc chamber vaporizing. You will also see a slight shade of red 
and blue. As the light comes to temperature the flickering will subside, the arc will stabilize and 
the light output will increase. The Light emitted from the flashlight is a higher Kelvin 
temperature (blue in color) than ordinary flashlights. Full light output occurs in 10-15 seconds. 
If momentary shut off of the light is needed you can instantly restart the light without worry of 
damage or cool down. It is suggested not to “flash” the light, as this will shorten run time and 
lamp life. 

 

CHARGING THE FLASHLIGHT 

 

1.

 

Before charging, power off the HID flashlight. It is to remain powered off while charging. 

2.

 

Charger stand required to charge EP batteries. Open the rubber waterproof cover 
located at the bottom of the light (on end cap), connect the male jack of charger to the 
female receptacle of the flashlight.  

CAUTION:

 Use only the supplied flashlight chargers; do not use other chargers as this 

will cause battery failure, overheating and possibly explosion. 

3.

 

Connect the charger plug to AC wall power or the DC power source (if DC charger is 
being used). 

4.

 

Charging time will be approximately 2.5 hours. 

5.

 

When the charge is complete, (indicated by Green LED), unplug the charger from the 
power source and disconnect the battery jack from the flashlight. Replace the rubber 
cap of the female receptor (on end cap) to prevent water from seeping in. 

6.

 

The optional Battery Charger Stand may be used to charge a spare Lithium Battery with 
either the AC or DC battery chargers. 

 

NOTE: 

 

When charging for long periods of time, the charger and battery will get hot. This is normal. If 
excessive heat or odor is noticed, disconnect the charger immediately.  

 

The charger uses a 2-color LED indicator (Red and Green)  

 

When connecting power, the LED will illuminate 

Green

.  

 

While charging, the LED will illuminate 

Red

.  

 

When fully charged the LED will again illuminate 

Green

.  

Do not leave the light or battery on charger past full charge or the overcharge circuit protection 
will activate.  
 

Отзывы: