If Track Guide is enabled, the Track Guide will simulate “real-
time” based on the difference between 1st and 2nd warning 
at speed 120mph
(176 feet/sec) or 193 km/h (54 m/sec). 
To stop the Test Warning Sounds, press  , 

 or 

 .

NOTE: In case of low battery capacity the volume will auto-
matically switch to ”1” and it cannot be changed until the 
batteries have been replaced.

Feet/Meters

Press   again. 
The FT or MT indicator located in the altitude area of the 
Main Window will begin to fl ash. 
Press 

 or 

 to switch between feet (FT) or meters (MT).

Power OFF

The QUATTRO can be manually powered OFF to further extend 
the battery life time when not in use. 
Press   again. 
The OFF icon in the icon area of the Main Display will begin 
to fl ash. 
Press and hold 

 and 

 until the display fl ashes, then 

release. 
The QUATTRO switches OFF. 
Customer settings (except altitude offset) are stored in 
nonvolatile memory when the QUATTRO is powered OFF. 
When powered OFF, the QUATTRO cannot be used for jump-
ing.

Canopy Descent and

Low Speed Warnings Selector

Description

The QUATTRO includes three canopy low speed warning 
sounds (short beeps sound when passing through one, two 
or three selectable altitudes) which can be selected to sound 
while under canopy descent or during wing suit fl ight.

Setting Canopy Descent Warnings

NOTE: Minimum selectable height is 100 ft (30 meters) 
Note: Default values 1200 ft., 900 ft., and 600 ft. have been fac-
tory preset for Canopy Descent Warning altitudes. 

In the Main Window mode, press   to access the Canopy 
Descent Selector. 
In this window perform ACCESS.

Warning Bank Menu Functions

The QUATTRO has four canopy descent warning banks. 
When the warning bank icon is fl ashing, press or to select 
warning bank 1 to 4. 

Setting the Warning Alarm Altitudes

The setting of altitudes in each warning bank can be per-
formed either on the ground or in the airplane during climb 
to jump altitude.
 

Three Warning Alarms

1. Press 

 

 until 1st warning altitude fl ashes 

2. Press 

 or 

 to change 1st warning altitude 

3. Press 

 

 again and the 2nd warning altitude fl ashes 

4. Press 

 or 

  to change 2nd warning altitude 

5. Press 

 

 again and the 3rd warning altitude fl ashes 

6. Press 

 or 

 to change 3rd warning altitude 

Two Warning Alarms

You can choose to only have two warning alarms. The proce-
dure is the same as above, but choose same altitude for the 
1st and 2nd warning alarms 
(the QUATTRO then sounds only the 2nd and 3rd warning 
alarms). 

One Warning Alarm

If you want only one warning alarm, choose same altitude 
for all three warning alarms using the above procedure. (The 
unit sounds only the 3rd warning alarm). 

Sound Pitch

Press   again. The musical note icon and pitch bar graph 
will begin to fl ash. 
Press 

 or 

 to change the pitch up or down. The pitch 

bar graph will display the number of bars corresponding to 
the selected pitch and the selected pitch will sound. 

NOTE: When selecting a pitch on either side of the center 
vertical bar (3,800 Hz), the output volume decreases about 5 
dB because the speaker is no longer at its optimum resonance 
frequency.

Sound Volume

Press   again.
Press 

 or 

 to select output volume for all three 

canopy low speed warnings. 
 
”1” is very low volume (112 dB),”10” is very high volume 
(117 dB) 
The QUATTRO is factory preset to ”3”. 

NOTE: In case of low battery capacity the volume will automatically 
switch to ”1” and it cannot be changed until the batteries have 
been replaced.

Test Alarm Sounds

Press   again. 
The ”Ear” icon will begin to fl ash. 
Press 

 or 

. This causes the QUATTRO to sound the 

preset alarm sequence at the selected pitch. 

NOTE: When Canopy Descent is enabled, the LO SPD icon will show 
in the warning bank area of all warnings. 
To disable LO SPD, set all warnings to ---

Climb to Altitude Warnings and Altitude 

Offset Selector 

Description

The altitude during climb at which the beep is heard may be 
changed or up to three different altitudes during climb may 
be selected for beep sounds. 
At the lowest preset altitude (factory preset to 1,000 feet), 
the QUATTRO sounds a sequence of beeps. These beeps have 
two functions: 

1. The beeps indicate that the QUATTRO has calibrated itself 
to the local ground elevation and is ready to jump. 

2. The number of beeps indicates the altitude at which the 
highest warning alarm is set; for example: If set to 4,500 
feet, the signal will sound: beep-beep-beep-beep-(pause)
beep. 
The number of rapid-sequence of beeps indicates the highest 
warning altitude in thousands of feet. The beep after a 
pause (if any), signifi es a 500-foot altitude increment. 
Should the battery voltage of the QUATTRO show low capac-
ity, the beep sequence is followed by 5 short beeps. This 
indicates that the batteries should be replaced. 

NOTE: At the same time the output volume setting is automatically 
changed to low volume “1” and it cannot be changed until the 
batteries have been replaced. 
When the aircraft begins climbing to altitude, the QUATTRO displays 
the current altitude at the top of the display. 

Setting

The setting of warning altitudes can be performed either on 
the ground or in the airplane during climb to jump altitude.
 

Setting Climb to Altitude Warnings and Altitude Offset

NOTE: Minimum selectable height is 1000 ft (300 meters) 
Note: Default values 1000 ft., --- ft., and --- ft. have been factory 
preset for Climb to Altitude Warnings. 

In the Main Window mode, press

 to access the Climb to 

Altitude Warnings and Altitude Offset Selector. 
Perform ACCESS in this window.

Three Warning Alarms

1. Press 

 

 until 1st warning altitude fl ashes 

2. Press 

 or 

 to change 1st warning altitude 

3. Press 

 

 again and the 2nd warning altitude fl ashes 

4. Press 

 or 

 to change 2nd warning altitude 

5. Press 

 

 again and 3rd warning altitude fl ashes 

6. Press 

 or 

 to change 3rd warning altitude 

Sequence of Climb Warning Alarm Altitudes

You may note that when setting the warning altitudes, it is 
possible to set the 1st warning alarm altitude lower than 
the 2nd or even the 3rd warning altitudes. The 2nd warning 
altitude could be set to a higher value than the 1st warning 
altitude or a lower value than the 3rd warning altitude, and 
so on. This is not a problem – when the QUATTRO exits 
ACCESS mode, it will automatically sort and store the warn-
ing alarms such that the highest warning altitude become 
the 1st warning alarm, the next highest warning altitude 
becomes the 2nd warning alarm, and the lowest warning 
altitude becomes the 3rd warning alarm. 

One or Two Warning Alarms

If you wish only one warning alarm or two alarms, preset the 
not used alarm(s) to --- 

Altitude Offset 

Explanation: 
If the DZ elevation differs from that of the airport of takeoff, 
use the altitude offset capability to set the DZ elevation 
prior to entering the airplane or set the altitude offset to 
zero when climbing through the DZ elevation. 

Press 

 

 again. The altitude (normally 0) next to the FT or 

MT indicator will begin to fl ash.
 
Press 

 or 

 to set an altitude offset to match the 

altitude of the landing DZ relative to the takeoff airport. 

NOTE:

 When performing manual altitude offset the QUATTRO 

enters Jump Mode and retains the altitude offset for 14 hours, 
if no jump is made. After 14 hours the QUATTRO recalibrates 
to the fi eld elevation where it is currently located and once 
again displays 0. The altitude offset is not retained when the 
QUATTRO is powered OFF. 

OPERATIONAL CONSIDERATIONS

Prior to Jumping

The QUATTRO continually adjusts to the local elevation and 
displays 0 FT (MT) at the top of the display. If the top of the 
display does not show “0” (or your selected altitude offset) 
prior to jumping, the unit has not adjusted itself to the local 
elevation and it must be manually zeroed. See the section, 
“Altitude Offset Function” under Menu functions above. 
Even when the display turns OFF, the unit is still ready for 
jumping.

Setting an Altitude Offset

If the drop zone (DZ) elevation is different from that of the 
takeoff airport, you may compensate for this difference by 
setting an Altitude Offset – see the Altitude Offset menu 
function described above. 

Battery Status

Full capacity: Symbol shows two black bars inside the bat-
tery icon. 

Half capacity: Symbol shows one black bar inside the battery 
icon. 

Low capacity: Symbol shows no black bars, just an “empty” 
battery icon. Batteries should be replaced as soon as pos-
sible. 

As a reminder, 5 short beeps sound when climbing through 
the lowest preset climb altitude. At the same time the 
output volume setting is automatically changed to low 
volume “1”. 
Empty batteries: The battery icon fl ashes. Replace batteries 
immediately.

Mounting the QUATTRO

The QUATTRO can be mounted on the outside of the helmet. 
Loop the wax cord through the four mounting holes and 
fasten with knots to the helmet. 

NOTE: Make sure that there is no material between the 
QUATTRO loudspeaker hole and your ear.

Resetting the QUATTRO

     
Press a paperclip into the tiny hole on the rear side of the 
unit and release. The unit restarts. 

NOTE: Reset the unit after battery replacement, when trouble-
shooting and when verifying software version number.

Air Filter 

The QUATTRO is water resistant. 
The Air Filter is the white circular part mounted on the side 
of the unit. If it becomes wet (after a splash in the swoop 
pond) then let the QUATTRO dry in a warm place for 48 
hours. 

NOTE: The Air Filter must be replaced if jumping is resumed 
quickly or if the QUATTRO has been submerged into water. 
Air Filter removal tooling kit is an accessory which can be 
purchased separately. 

QUATTRO Firmware Version

Perform reset. The version number is displayed at the upper 
part of the screen (altitude area). The numbers displayed in 
the middle of the screen is a factory reference number. 

Battery replacement

                     
Carefully remove screw from battery cover and remove 
batteries. 
Install new batteries and note polarity. 
Use only Renata CR-2325. 

NOTE: Reset the QUATTRO after replacing batteries. 
Customer settings are kept in non-volatile memory when 
removing batteries. However, the built-in clock may again be 
set to the correct time. 

Trouble-shooting

When the QUATTRO detects a fault, an error (“ERR”) sign and 
troubleshooting number 2 to 4 are displayed in the upper 
part of the screen. At the same time the unit beeps every 
minute. 

The “ERR” trouble shooting codes are as follows: 
ERR 2, ERR 3, ERR 4 = unit is defective. Remedy: perform 
reset 

If the unit does not function correctly even after replacing 
batteries and pressing reset, perform following: 
Press 

 

 and hold while resetting. 

The QUATTRO resets to factory settings and sounds three 
beeps. 
If the unit is still faulty, please contact your local dealer or 
LARSEN & BRUSGAARD. 

SPECIFICATIONS

Dimensions: 52 x 40 x 12 mm (2.16 x 1.57 x 0.47 inches) 
Weight: 26 grams (0.9 oz.) 
Battery type: 2 x Renata CR 2325
Battery Life Time: 2.5 years or 500 jumps 

Freefall alarm sounds:
1st warning: 
One 1.5 second pulsating alarm if vertical airspeed exceeds 
13 m/ sec at preset altitude. Sound sequence: Pulsating, low 
repetition.  
2nd warning: 
One 3 second pulsating alarm if vertical airspeed exceeds 13 
m/ sec at preset altitude. Sound sequence: Pulsating, low 
repetition. 
3rd warning: 
One 4 second pulsating alarm if vertical airspeed exceeds 13 
m/sec at preset altitude. Sound sequence: Pulsating, high 
repetition. 
4th warning: 
Siren alarm as long as vertical airspeed exceeds 13 m/sec at 
or below the preset altitude. After deployment the trigger 
speed switches to 35 m/sec. 
Sound sequence: High pitch continuous siren. 
Track Guide:
0.5 second beeps between 1st and 2nd warning.

Low Speed alarm sounds: 
1st warning: One 0.2 second beep 
2nd warning: Two 0.2 second beeps 
3rd warning: One 1.3 second beep 

Climb to Altitude Warnings: Two 0.2 second beeps 

Alarm output volume: 
117 dB at maximum volume “10”
112 dB at minimum volume “1” 

Freefall alarm calibration range: 1,000 to 19,900 feet (300 
to 6,000 meters) 

Low speed alarm calibration range: 100 to 9,990 feet (30 to 
3,330 meters)
 
Climb to Altitude calibration range: 1000 to 9,990 feet (300 
to 3,330 meters)

Altitude selection interval: 10 feet (10 meters) 

Operating altitude: 0 to 40,000 feet 

Accuracy: +/- 1.2%
Operating Temperature Range: -20° C to +50° C (-4° F to 
+122° F) 

Meets or exceeds EEC/89/336 

L&B part no.: 205222 

NATO Stock no.: 6605-22-609-1694 

Отзывы: