ETHERLINE® GUARD PM03T / ETHERLINE® GUARD 
PM02TWA 

Revision 1 from HW 1 / 18.11.2021 

Area of application 

The ETHERLINE® GUARD can be used to monitor Ethernet-based data cables with a transmission speed 
of 100 Mbit/s (100Base-TX). The ETHERLINE® GUARD is inserted into the cable harness and can provide 
information about the quality of the cable connection via a separate network connection (LAN or Wi-Fi) or 
via a digital output. 

The 

current product documentation

 with the safety information and for the complete device 

setup, as well as the applicable EU 

conformity

 

declaration

, can be found on the product 

website: www.la

pphungaria.hu/etherline-guard

Connections 

The ETHERLINE

®

 GUARD has 2 RJ45 connections (DATA) for 

the cable to be monitored and a LAN connection (PM03T) or 
an antenna connection for Wi-Fi (PM02TWA). 

The ETHERLINE

®

 GUARD must be supplied at the 18 to 

30 V DC wide range input via the supplied 24 V DC connector. 
Pins 1 (GND) & 2 (VCC) (- / +) must be correctly connected. 

The ETHERLINE® GUARD housing is not 
earthed. It is vital that you connect the device's 
functional earthing connection (FE) to the 
reference potential of your control cabinet or 
system design to ensure correct ESD discharge of the antenna and network sockets. 

The device should be installed and operated at a distance of at least 20 cm between the 
emitter/antenna and your body. 

The device must not be used as the sole means of avoiding hazardous conditions at 
machines and systems. 

If the device is used in a way not specified by the manufacturer, the protection offered by the 

device may be impaired. Please pay particular attention to correct contacting when assembling cables. 
Should you have any issues, always read the latest documentation first. Connected circuits must meet the 
requirements for circuits with limited energy according to UL61010-1. 

Initial setup 

Please connect the device to the power supply. You must also observe the information above about using 
functional earth (FE). As soon as the DATA connections are connected via Ethernet-based cables and the 
links are established (see ports of the RJ45 connections), a teach-in must be performed to ensure that the 
device works correctly (this also applies during every cable replacement). To do this, please press the Set 
button for 20 seconds. As soon as the PWR and STATUS LED light up red, the teach-in is carried out.  

Press and hold SET 

(release for selection) 

After 3 seconds 

Set Wi-Fi 

(available for PM02TWA) 

PWR emits a steady red 
light. 

Wi-Fi lights up blue 
according to the function. 

After 20 seconds 

Teach-in 

PWR and STATUS emit a 
steady red light. 