2: Functional Description
xPico® Embedded Device Server Integration Guide
24
Figure 2-8 Serial Port Example
Table 2-9 RS232 Connections (Serial Transceiver Required)
xPico Signal
DCE Connector
DTE Connector
Signal
(Logic)
Description
DB9 DB25
Signal
DB9
DB25
Signal
RXDx
Data In
2
3
RXDx
3
2
TXDx
TXDx
Data Out
3
2
TXDx
2
3
RXDx
RTSx
H/W Flow Control Output
7
4
RTSx
8
5
CTSx
CTSx
H/W Flow Control Input
8
5
CTSx
7
4
RTSx
CPx
Modem Control Input
1
8
DCDx
4
20
DTRx
CPy
Modem Control Output
4
20
DTRx
1
8
DCDx
Table 2-10 RS422/485 Connections (Serial Transceiver Required)
xPico
Signal
(logic)
Description RS485
Signal
DB25 4
Wire
DB25 2
Wire
DB9 4
wire
DB9 2
wire
TXDx
Data Out
TX+485
14
14
7
7
TXDx
Data Out
TX-485
15
15
3
3
RXDx
Data In
RX+485
21
14
2
7
RXDx
Data In
RX-485
22
15
8
3
RTSx
TX Enable
CPx
RS485 Select
CPy
RS485 2-wire
Note:
The IO pins for xPico Wi-Fi embedded device server are set to floating
input on power up until configured by unit firmware. An external 100K ohm pull-
up may be required on the serial transmit signal to prevent downstream UART