![Lantronix TN-SFP 25G R-S Series Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/lantronix/tn-sfp-25g-r-s-series/tn-sfp-25g-r-s-series_user-manual_3646825012.webp)
Lantronix
TN-SFP-xx25G-xR-S Series User Guide
33815 Rev. C
Page 12 of 16
voltage. Data is assumed to be based on measurement of a laser monitor
photodiode current. Data is not valid when the transmitter is disabled.
Mon3 (RX PWR)
Displays the measured received optical power in mW. Absolute accuracy is
dependent upon the exact optical wavelength. For the vendor specified wavelength,
accuracy should be better than 3dB over specified temperature and voltage. This
accuracy should be maintained for input power levels up to the lesser of maximum
transmitted or maximum received optical power per the appropriate standard. It
should be maintained down to the minimum transmitted power minus cable plant
loss (insertion loss or passive loss) per the appropriate standard. Absolute
accuracy beyond this minimum required received input optical power range is
vendor specific.
SFP Detail Info
This page displays detailed SFP information and monitoring information as shown and described below.
Parameter descriptions
:
Parameter
Description
Connector Type
Displays the external optical or electrical cable connector provided as the media
interface.
Fiber Type
Displays the fiber channel transmission media.
Tx Central
Wavelength
Displays the nominal transmitter output wavelength in nm.
Bit rate
Displays the nominal bit rate of the transceiver.
Vendor OUI
Displays the vendor IEEE company ID (Organizationally Unique Identifier).