Lantronix SM8TAT2SA Скачать руководство пользователя страница 2

 

 

SMxxTAT2SA Quick Start Guide

 

33715 Rev. E 

                  

https://www.lantronix.com

   

Page 

2

  of 

2

   

First Time Wizard Configuration   

The first time you use the switch you can configure some basic settings, such as password, IP address, date and 

time, and system information. To use the First Time Wizard procedure: 

Step 1

: Change default password; enter a new password and then enter it again and click the 

Next

 button.   

Step 2

: Set IP address; select “Obtain IP address via DHCP” or “Set IP address manually” to set the IP address, 

and click the 

Next

 button.     

Step 3

: Set date and time; enable “Automatic data and time” or select manually to set date and time and click 

the 

Next

 button. 

Step 4

: Set system information; here you can set some system information to this device, such as “System 

contact”, “System name”, etc. When done click 

Next

Note

: The First Time Wizard is used the first time you use the switch and after pressing the Reset 

button. 

Note

: The factory default IP address = 192.168.1.77, default Subnet Mask = 255.255.255.0, Default 

Gateway = 192.168.1.254, default Username = admin, and default Password = admin. 

Web UI Configuration

   

The left-hand menu contains two main tabs (Switch and DMS) each with several 

sub-tabs for configuring and monitoring major switch functions. The major Switch 

tab functions include Port, PoE, VLAN Management, QoS, Spanning Tree, 

Diagnostics, and Maintenance. The DMS (Device Management System) tab 

functions are DMS Mode, Graphical Monitoring, Management, and Maintenance. 

See the Web User Guide. 

CLI Configuration

   

The command-line interface (CLI) is a text-based interface that you can access with 

either a direct serial connection to the device or a Telnet session. An RJ-45 cable is 

used for connecting a terminal or terminal emulator to the SMxxTAT2SA RJ-45 port 

to access the command-line interface. Attach the RJ-45 serial port on the switch 

front panel to the cable for Telnet/CLI configuration. Attach the other end of the 

DB-9 cable to a PC running Telnet. Note that the CLI can only be accessed via telnet 

or SSH. See the CLI Reference. 

 

Related Documentation

: SMxTAT2SA Install Guide 33716, Web User Guide 33717, CLI Reference 33718.   

Release Notes (version specific). 

Contact Us

: Toll Free: 800-526-8766. Phone: 949-453-3990. Fax: 949-453-3995.   

Technical Support: 

http://www.transition.com/support

. Sales Offices: 

www.lantronix.com/about/contact

. 

© 2021 Lantronix, Inc. All rights reserved. No part of the contents of this publication may be transmitted or 

reproduced in any form or by any means without the written permission of Lantronix. Lantronix is a registered 

trademark of Lantronix, Inc. in the United States and other countries.   
Patented: 

patents.lantronix.com

; additional patents pending. All other trademarks and trade names are the 

property of their respective holders.

 

 

Отзывы: