8: Device Ports
SLC™ Console Manager User Guide
97
Data Settings
Note:
Check the serial device’s equipment settings and documentation for the proper
settings. The device port and the attached serial device must have the same settings.
Authentication
If selected, the SLC unit requires user authentication before granting access to
the port.
Authenticate
is selected by default for
Telnet
in and
SSH in
, but not for
TCP in
.
Timeout
To cause an idle Telnet, SSH or TCP connection to disconnect after a specified
number of seconds, select the checkbox and enter a value from 1 to 1800
seconds. The default is no timeout.
Seconds
Number of seconds before a timeout.
IP Address
/Netmask Bits
IP address used for this device port so a user can Telnet, SSH, or establish a raw
TCP connection to this address and connect directly to the device port. The
optional netmask bits specify the netmask to use for the IP address. For
example, for a netmask of 255.255.255.0 specify 24 bits. If the netmask bits are
not specified, a default netmask used for the class of network that the IP address
falls in will be used.
For Telnet and SSH, the default TCP port numbers (22 and 23, respectively) are
used to connect to the device port. For raw TCP, the TCP port number defined
for
TCP In
to the device port is used.
Note:
If Ethernet Bonding is enabled, assigning individual IP Addresses to
Device Ports is not supported. Note that the IP address will be bound to Eth1
only, so if Eth2 is connected and configured, and Eth1 is not, this feature will not
work.
Web SSH/Telnet
Columns
Number of columns in the Web SSH/Telnet applet when this device port is
accessed via the applet.
Rows
Number of rows in the Web SSH/Telnet applet when this device port is accessed
via the applet.
Baud
The speed with which the device port exchanges data with the attached serial
device.
From the drop-down list, select the baud rate. Most devices use 9600 for the
administration port, so the device port defaults to this value. Check the equipment
settings and documentation for the proper baud rate.
Data Bits
Number of data bits used to transmit a character. From the drop-down list, select
the number of data bits. The default is
8
data bits.
Stop Bits
The number of stop bit(s) used to indicate that a byte of data has been transmitted.
From the drop-down list, select the number of stop bits. The default is
1
.
Parity
Parity checking is a rudimentary method of detecting simple, single-bit errors.
From the drop-down list, select the parity. The default is
none
.
Flow Control
A method of preventing buffer overflow and loss of data. The available methods
include none, xon/xoff (software), and RTS/CTS (hardware). The default is
none
.
Enable Logins
For serial devices connected to the device port, displays a login prompt and
authenticates users. Successfully authenticated users are logged into the
command line interface.
The default is disabled. This is the correct setting if the device port is the endpoint
for a network connection.
Max Direct Connects
Enter the maximum number (1-10) of simultaneous connections for the device
port. The default is 1.
Содержание SLC16
Страница 1: ...Part Number 900 449 Revision J July 2014 SLC Console Manager User Guide SLC8 SLC16 SLC32 SLC48 ...
Страница 95: ...8 Device Ports SLC Console Manager User Guide 95 Figure 8 4 Device Ports Settings ...
Страница 150: ...10 USB Port SLC Console Manager User Guide 150 Figure 10 3 Devices USB Modem 3 Enter the following fields ...
Страница 217: ...13 Maintenance SLC Console Manager User Guide 217 Figure 13 1 Maintenance Firmware Config ...