Power Supply Installation 

Each power supply is a DIN rail power supply with a 150% peak load capability (3 seconds) and high efficiency of 

up to 94%. They can be mounted on a TS35 Standard DIN rail. 
1

Always allow good ventilation clearances (5mm left and right, 40mm above and 20mm below) around the 

unit in use to prevent it from overheating. Also a 10-15 cm clearance must be kept when the adjacent device is a 

heat source. 
2

The appropriate mounting orientation for the unit is vertical, the input terminals at the bottom and output on 

the top. Mounting orientations other than that, such as upside down, horizontal, or table-top mounting, is not 

allowed. 

 

3

Use copper wire only, and recommended wires as shown below. 

AWG 

18 

16 

14 

12 

10 

Rated Current of Equipment 

(Amps) 

6A 

6-10A 

13-16A 

16-25A 

25-32A 

Cross-section of Lead (mm

2

0.75 

1.00 

1.5 

2.5 

Note 1. Current: each wire should be de-rated to 80% of the current suggested above when using 5 or more 

wires connected to the unit. 

Note 2: The maximum allowable wire cross-sectional area for the terminal of 

the SDR-75 

is 12AWG/2.5 mm

2

4) Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals 

are securely fixed to prevent poor contact. If the power supply possesses multi-output terminals, please 

make sure each contact is connected to wires to prevent too much current stress on a single contact. 
5

Use wires that can withstand temperatures of at least 80

°

C, such as UL1007. 

6

Recommended wire strapping length is 5mm (0.197”). 

7

Recommended screwdriver is 4mm, slotted type. 

8

The recommended torque setting for terminals is: 

 

SDR-120-24 I/P = 6.3 kgf-cm (5.5 Lb-in) and O/P = 8 kgf-cm (7 Lb-in) 

 

SDR-240-48 I/P = 5 kgf-cm (4.4 Lb-in) and O/P = 8 kgf-cm (7 Lb-in) 

9

Suggested fuse and maximum number of the SDR PSUs that can be connected to a circuit breaker at 230V 

are: 

 

SDR-120-24 Fuse = T4A/L250V, C16 = 7, D16 = 14. 

 

SDR-240-48 Fuse = T5A/L250V, C16 = 4, D16 = 8. 

10) Adjust the power supply output voltage if the switch won’t power up.   

 

 

 

 

 

Содержание SISGM1040-284-LRT

Страница 1: ...SISGM1040 284 LRT Managed Hardened Gigabit Ethernet Switch 8 10 100 1000Base T Ports 4 100 1000Base X SFP Slots Install Guide Part Number 33808 Revision E October 2022 ...

Страница 2: ...y completeness usefulness suitability or performance of the information provided herein Lantronix shall have no liability whatsoever to any user for any damages losses and causes of action whether in contract or in tort or otherwise in connection with the user s access or usage of any of the information or content contained herein The information and specifications contained in this document are s...

Страница 3: ...ix does so at their own risk and agrees to fully indemnify Lantronix for any damages that may result from such use or sale Attention This product like all electronic products uses semiconductors that can be damaged by ESD electrostatic discharge Always observe appropriate precautions when handling Note Emphasizes important information or calls your attention to related features or instructions Cau...

Страница 4: ...g the DI DO Digital Input Digital Output Relay 24 Digital Input and Digital Output Use Case 25 Ground Screw 26 RESET Button 26 Console Port 26 DIP Switch Ring Settings 27 Power Supply Information 27 Power Supply Warnings Cautions 27 Power Supply Specifications 28 Industrial Power Supply 25165 29 Industrial Power Supply 25130 30 PS DC DUAL 5624T Stand Alone Hardened Power Supply 32 SPS UA12DHT Indu...

Страница 5: ...nnovation Science and Economic Development Canada ICES 003 Compliance Label 42 RoHS WEEE and Environmental Programs 42 Declaration of Conformity 42 Cautions and Warnings 42 Appendix A Rapid Ring Operation 43 Rapid Ring Operation 43 Hardware Setting and Status for Rings 43 RM and RC LED Descriptions 44 ...

Страница 6: ...031 Ethernet Linear Protection Switching EPS ITU T G 8032 Ethernet Ring Protection Switching ERPS Media Redundancy Protocol MRP IEEE 1588v2 PTP IEEE 802 3ah OAM IEEE 802 1ag CFM ITU T Y 1731 Performance monitoring DHCP Server IEEE 802 3az Energy Efficient Ethernet for green Ethernet applications IPv4 IPv6 L3 static route 8 port 10 100 1000Base T and 4 100 1000 SFP slots Power input range dual 12 4...

Страница 7: ... switch is designed to help save power with Energy Efficient Ethernet IEEE 802 3az It can be used to build a green Ethernet networking environment Ordering Information SKU Description SISGM1040 284 LRT Hardened Managed Switch 8 10 100 1000Base T 4 100 1000Base X SFP Slots Optional Accessories Order Separately Power Supply 25165 Industrial DIN Rail Mounted Power Supply ConsoleFlow Centralized Manag...

Страница 8: ...unds 62 x 135 x 130 2 4 x 5 3 x 5 1 0 66 switch 0 975 switch pkg 1 45 switch 2 15 switch pkg DIN rail Voltage and Frequency Primary Power Supply DC Input Voltage DC Nominal 12 24 48 VDC dual inputs DC Operating Range 12 to 48 VDC Certifications Regulatory Compliance EMS EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 CS EN61000 4 8 PFMF EMI FCC Part 15 Class A Safety C...

Страница 9: ...Display visual chart of network traffic of all devices and monitor all ports at any time Troubleshooting Network diagnostic between Master Controller switch and devices Check Connection status and Cable status quickly and easily Ethernet OAM IEEE 802 3ah OAM Supports Operations Administration Management IEEE 802 1ag ITU T Y 1731 Flow OAM Supports IEEE 802 1ag Ethernet CFM Connectivity Fault Manage...

Страница 10: ...hash guest VLAN single multiple host mode and single multiple sessions Supports IGMP RADIUS based 802 1X Dynamic VLAN assignment Layer 2 Isolation Private VLAN Edge PVE also known as protected ports provides L2 isolation between clients in the same VLAN Supports multiple uplinks Port Security Locks MAC addresses to ports and limits the number of learned MAC address IP Source Guard Prevents illegal...

Страница 11: ...ession is supported UPnP The Universal Plug and Play Forum is an industry group of companies working to enable device to device interoperability by promoting Universal Plug and Play s Flow The industry standard for monitoring high speed switched networks It gives complete visibility into the use of networks enabling performance optimization accounting billing for usage and defense against security...

Страница 12: ...nign Controlled 25 C 951 258 Hrs GB GC Ground Benign Controlled 75 C 193 332 Hrs DC Power Consumption Measured DC power consumption after 60 minutes under full loading with wire speed forwarding 12 VDC Input Device Status Operation Interface DC Current Consumption A DC Voltage V DC Power Consumption W Non loading None 0 43 12 5 16 Standby mode 1G TP Port x 8 1G SFP Port x 4 0 77 12 9 24 Full loadi...

Страница 13: ...8 Full loading 60 minutes later 1G TP Port x 8 1G SFP Port x 4 0 22 48 10 56 Application Example The SISGM1040 284 LRT switch is shown below in Industrial IOT and Surveillance applications About This Manual This manual describes how to install configure and troubleshoot the switch including how to Install the switch Check switch status by reading the LED behavior Reset or restore the switch to fac...

Страница 14: ...es for which Lantronix is not responsible Laser Safety Instructions When a connector is removed during installation testing or servicing or when an energized fiber is broken a risk of ocular exposure to optical energy that may be potentially hazardous occurs depending on the laser output power The primary hazards of exposure to laser radiation from an optical fiber communication system are Damage ...

Страница 15: ...rent status of each port Check these LEDs to determine the port status The following tables details the functions and descriptions of these LED indicators Table 1 Power LEDs LED Color State Description P1 Power1 Green On The switch is powered ON correctly Off The switch is not receiving power from power1 P2 Power2 Green On The switch is powered ON correctly Off The switch is not receiving power fr...

Страница 16: ... V1 PHY TTL LED SFP max 3 465V min 3 135V 5 V2 MAC max 2 625V min 2 375V 5 V3 MAC DDR max 1 575V min 1 425V 5 V4 MAC max 1 05V min 0 95V 5 Issue critical stage for High Temperature alarm Lit Alarm LED in RED Color if Test point max temperature max 100 C You can view temperature and voltage settings at Monitor Port SFP Detail Info You can you view and configure current trap event severity parameter...

Страница 17: ...he connection speed is 10 100Mbps Off The port has no active network cable connected or it has not established a link to a connected device Otherwise the port may have been disabled via the switch user interface SFP Ports Green On The port is enabled and has established a link to a connected device and the connection speed is 1000Mbps Green Blinking The port is transmitting receiving packets and t...

Страница 18: ...pid Chain LEDs LED RM Ring Master RC Rapid Chain Off disable disable Green Ring Master is Enabled Rapid Chain Active path Amber Ring Slave is Enabled Rapid Chain Backup path Blink Amber Error More than one Master in this ring Error Rapid Chain Switch did not find the other Rapid Chain Switch partner active backup ...

Страница 19: ...ions on page 17 and Power Supply Warnings Cautions on page 27 before proceeding Package Checklist Verify that the box contains the following items One Managed Ethernet Switch One DIN Rail Clip Three Screws for DIN Rail Clip One DB9F to RJ45 Console cable One printed Quick Start Guide One documentation postcard Contact your sales representative if you have not received these items Save the packagin...

Страница 20: ...E https www lantronix com 20 DIN Rail Mounting Mounting steps 1 Screw the DIN Rail bracket on with the bracket and screws in the accessory kit 2 Hook the unit over the DIN Rail 3 Push the bottom of the unit towards the DIN Rail until it snaps into place ...

Страница 21: ...uide 33808 Rev E https www lantronix com 21 Wall Mounting The Wall Mount Bracket WMBH 01 is an optional accessory that you must order separately Mounting steps 1 Screw on the wall mount plate with the plate and screws in the accessory kit ...

Страница 22: ...s of electrical interfaces RJ45 and optical mini GBIC Connecting the Ethernet interface via RJ45 To connect to a PC use a straight through or a cross over Ethernet cable To connect the SISGM1040 184D LRT to an Ethernet device use UTP Unshielded Twisted Pair or STP Shielded Twisted Pair Ethernet cables The pin assignment of RJ 45 connector is shown below ...

Страница 23: ...red laser light at this point Caution We strongly recommend that you do not install or remove the SFP module with fiber optic cables attached to it because of the potential damage to the cables the cable connector or the optical interfaces in the SFP module Disconnect all cables before removing or installing an SFP module For more information see the Lantronix manual specific to your SFP on the La...

Страница 24: ... blade screwdriver to tighten the wire clamp screws on the front of the Terminal Block connector 3 Insert the Terminal Block connector prongs into the Terminal Block receptor Note Digital output relay 24VDC 1A Digital input level 0 Low 0V to 6V level 1 High 10V to 24V FAULT The two contacts of the terminal block connector are used to detect user configured events The two wires attached to the faul...

Страница 25: ...ime DO will automatically switch to abnormal and send a signal to connected devices switch will have system recorded Water level application example Setting low water level DI normal High water level DI abnormal DIO connected to external alarm notification DI will show normal when the water level is low DI will not send signal to DO DI will show abnormal when sensor senses high water level and wil...

Страница 26: ...s provided to reboot the system without the need to remove power Under normal circumstances you will not have to use it However on rare occasions the switch may not respond and you may need to push the Reset button Console Port The Console port is for local management by using a terminal emulator or a computer with terminal emulation software DB9 connector connect to PC COM port Baud rate 115200bp...

Страница 27: ...ector s or terminal block s Power Supply Warnings Cautions 1 Risk of electrical shock and energy hazard All failure should be examined by a qualified technician Please do not remove the case of the power supply by yourself 2 Risk of electric arcs and electric shock danger to life Connecting both the primary and the secondary sides together is not allowed 3 Risk of burn hazard Do not touch the unit...

Страница 28: ...able from Lantronix Note that a Power Supply is not included sold separately Warning You must use an isolated power supply in order for Lantronix to honor the warranty The power supplies that Lantronix makes available are Power Supply 25165 Power Supply 25130 SPS UA12DHT PS DC DUAL 5624T Each power supply model is described on the following pages ...

Страница 29: ...Setup Rise Time 500ms 50ms full load Output Hold Up Time 30ms 230VAC 12ms 115VAC at full load Input Voltage Range Switch Selectable 85 264VAC 120 370VDC Input Frequency Range 47 63Hz Input Efficiency 88 Input AC Current Typical 0 88A 115VAC 0 48A 230VAC Input Inrush Current Cold 25A 115VAC 45A 230VAC Protection Overload 105 160 Protection Overvoltage 15 18V Dimensions W 1 38 35 mm x D 2 15 54 5 mm...

Страница 30: ...Selectable 88 264VAC 120 370VDC Frequency Range 47 63Hz Efficiency 88 AC Current Typical 1 1A 115VAC 0 7A 230VAC Inrush Current Cold 30A 115VAC 60A 230VAC Leakage Current 1mA 240VAC Protection Overload 105 150 Overvoltage 57 6 64 8V LED Front panel DC OK LED lights green when DC output is good V Adj Recessed front panel screw to raise and lower output voltage Dimensions Width 1 57 40 mm x Depth 3 ...

Страница 31: ...Lantronix SISGM1040 284 LRT Install Guide 33808 Rev E https www lantronix com 31 25130 Layout and Dimensions 25130 Back Panel ...

Страница 32: ...ring o Fan tachometer monitoring for low speed or lock conditions o Over or under temperature o 12 24V output out of spec Specifications Output 1 Voltage 56V terminal block Regulation 2 Current Rating 5 7A Power Rating 315W Output 2 Voltage 24V terminal block 5624T Regulation 5 Current Rating 1 25A Power Rating 30W Input Frequency Range 47 63 HZ Power Consumption 4A at 120 VAC typical Dimensions W...

Страница 33: ...Drop Protection Overvoltage Regulated Protection Short Circuit Continuous Short Circuit Protect Dimensions Width 3 64 92 5 mm x Depth 1 54 39 mm x Height 1 54 39 mm Environment Operating Temp 0 C to 70 C Storage Temp 40 C to 70 C Humidity 10 to 95 non condensing Compliance Safety UL60950 1 CUL 60950 1 TUV EN60950 1 CE Mark J60950 Vibration IEC60068 2 6 EMC Emission FCC Part 15 Class B EN55022 Clas...

Страница 34: ...nly with input terminals down or else sufficient cooling will not be possible Admissible DIN Rail TS35 7 5 or TS35 15 For DIN Rail fastening 1 Tilt the unit slightly rearwards 2 Fit the unit over top hat rail 3 Slide it downward until it hits the stop 4 Press against the bottom for locking 5 Shake the unit slightly to check the locking action ...

Страница 35: ...nt each wire should be de rated to 80 of the current suggested above when using 5 or more wires connected to the unit Note 2 The maximum allowable wire cross sectional area for the terminal of the SDR 75 is 12AWG 2 5 mm2 4 Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact If the power supply possesses m...

Страница 36: ...onfigured insert the positive and negative wires into P2 and P2 contacts on the terminal block and tighten the wireclamp screws Note See Power Supply Warnings Cautions Power Supply Installation and Power Supply Mounting Instructions later in this manual for detailed information Note Make all cable connections before connecting Power Power Connector 4 Pin Terminal Block Input DC 12 58V P1 Power Inp...

Страница 37: ...indows you can run a terminal emulator such as PuTTY CLI Initialization and Configuration Optional 1 Connect a PC to the SISGM1040 284 LRT Ethernet port RJ45 Ethernet port 2 In Telnet enter the command telnet 192 168 1 77 3 Login with default account and password Username admin Password admin 4 Change the IP address with the CLI commands below enable configure terminal config interface vlan 1 conf...

Страница 38: ... Ethernet connection 5 Right click on it and go to Properties 6 On the Networking tab select Internet Protocol Version 4 TCP IPv4 7 Click on the Properties tab 8 Click the Use the following IP address button 9 Give the same IP subnet as the switch 192 168 1 5 your switch is 77 Subnet mask 255 255 255 0 10 Click OK 11 Connect your network cable from your PC to your switch 12 In your web browser add...

Страница 39: ...etting to factory defaults and or a system reset See the Reset Button on page 10 See the Web User Guide or the CLI Reference manual 6 Make sure that the function you are trying to use is supported See Features on page 4 7 Verify the install procedures were performed correctly as described in previous sections of this manual 8 Check that the proper cable type is used and its length does not exceed ...

Страница 40: ...___________________ Your Lantronix service contract number _________________________________________________ Describe the failure _________________________________________________________________________ _________________________________________________________________________________________ _________________________________________________________________________________________ ________________...

Страница 41: ...h FCC Method 47 CFR Part 15 Subpart B Class A Digital Device CISPR PUB 22 and Canada Standard ICES 003 Issue 6 Class A European Standard EN 55032 Class A Australian Standard AS NZS CISPR 32 Class A Harmonics European Standard EN 61000 3 2 Voltage Fluctuations EN 61000 3 3 EMS European Standard EN 55024 ESD IEC 6100 4 2 RS IEC 61000 4 3 EFT IEC 61000 4 4 Surges IEC 61000 4 5 CS IEC 61000 4 6 PFMF I...

Страница 42: ... Manufacture s Address 48 Discovery Suite 250 Irvine California 92618 Declares that the products SISGM1040 284 LRT Hardened Managed Ethernet Switch Conforms to the following Product Regulations FCC Part 15 Class A EN 55032 2015 AC 2016 Class A EN 61000 3 2 2014 EN 61000 3 3 2013 and EN 55024 2010 A1 2015 IEC 61000 4 2 Edition 2 0 2008 12 IEC 61000 4 3 Edition 3 2 2010 04 IEC 61000 4 4 Edition 3 0 ...

Страница 43: ...and Status for Rings DIP switch settings are shown and described below Note RM means Ring Master and RC means Rapid Chain Figure 9 DIP Switch Configure Rapid Ring by hardware DIP Switch as shown in the table below Table 1 DIP Switch Settings Mode RM RC Rapid Ring Status 1st Port 2nd Port RM LED RC LED HW Control OFF OFF Single Ring Member The largest Odd Port Number The largest Even Port Number Li...

Страница 44: ...Status LED Color State Description RM Ring Master Green On Ring Master has been detected in the switch Amber On Ring Member has been detected in the switch Off Disabled RC Rapid Chain Green On Rapid Chain has been detected in the switch Active path Amber On Rapid Chain has been detected in the switch Backup path Blinking Error There is no correspondent Rapid Chain Switch found Off Disabled ...

Страница 45: ... Suite 250 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support 1 952 358 3601 1 800 260 1312 or https www lantronix com technical support Sales Offices For a current list of our domestic and international sales offices go to the Lantronix web site at www lantronix com about contact ...

Отзывы: