Introduction 

The Power Supply provides 345W at 56VDC and is targeted for PoE applications. The Power Supply is fully compliant 

with IEEE 802.3af, at, and bt PoE standards for isolation. It provides a secondary fully-isolated 24V at 1.25A (30W) output 

for other equipment. 

 

Ordering Information 

Model 

Description 

PS-DC-DUAL-5624T 

Hardened 345 Watt Isolated Power Supply with 56VDC and 24VDC Dual Output

 

PS-DC-DUAL-5624T-

AL  

Hardened 345 Watt Isolated Power Supply with 56VDC and 24VDC Dual Output with 

Locked –NA Power Cord 

27274 

AC Power Cord with locking; -NA Line Cord 

3344 

AC Power Cord; non-locking; -NA Line Cord 

27275 

AC Power Cord with locking; -NA Line Cord, Right angle 

Features 

  Wide 100-240VAC input with externally accessible fuse 

  56 VDC output provides plenty of margin for the powered device (PD) to meet minimum PSE output voltage 

requirements: 

o

  IEEE 802.3af (44VDC, 12V margin) 

o

  IEEE 802.3at (50VDC, 6V margin) 

o

  IEEE 802.3bt (52VDC, 4V margin) 

  Desktop mountable / DIN rail form factor  

  Full compliance with the IEEE 2250 VDC PoE isolation requirements 

  Active fan speed control based on temperature (PWM) 

  Front panel LED for power supply status (Normal and Alarm) 

  2-Pin Alarm DC relay output monitoring five events:  

o

  Fan tachometer monitoring for low speed and lock conditions 

o

  Over- or under-temperature 

o

  24V output out of spec 

  UL approval 

  5 year warranty 

 

 

 

Содержание PS-DC-DUAL-5624T

Страница 1: ...PS DC DUAL 5624T 345 Watt Isolated Power Supply with 56VDC and 24 VDC Dual Output Install Guide Part Number 33788 Revision E January 2022 ...

Страница 2: ...fices For a current list of our domestic and international sales offices go to the Lantronix web site at www lantronix com about contact Disclaimer All information contained herein is provided AS IS Lantronix undertakes no obligation to update the information in this publication Lantronix does not make and specifically disclaims all warranties of any kind express implied or otherwise regarding tit...

Страница 3: ...NA Line Cord 7 3344 AC Power Cord non locking NA Line Cord 8 Connectors and LEDs 9 Dimensions 10 Power Cords 10 Front Panel Descriptions 11 2 Installation 12 Cautions and Warnings 12 Unpacking 13 Mounting 14 Grounding 14 Connecting POWER OUTPUT 14 Connecting AC INPUT 14 PWR Power LED 15 Fuse Replacement 15 Installing TN 16210 Ferrite 15 Related Manuals 16 Application Example 16 3 Related Informati...

Страница 4: ...274 AC Power Cord with locking NA Line Cord 3344 AC Power Cord non locking NA Line Cord 27275 AC Power Cord with locking NA Line Cord Right angle Features Wide 100 240VAC input with externally accessible fuse 56 VDC output provides plenty of margin for the powered device PD to meet minimum PSE output voltage requirements o IEEE 802 3af 44VDC 12V margin o IEEE 802 3at 50VDC 6V margin o IEEE 802 3bt...

Страница 5: ...requency Range 47 63 HZ Power Consumption 4 0A at 120VAC typical Dimensions HxWxD Width 6 25 159 mm x Depth 6 45 164 mm x Height 1 75 44 mm Weight 1 8 lbs 0 72Kg Environment Operating Temp 20 C to 70 C restricted 20 C to 50 C unrestricted Storage Temp 30 C to 70 C Operating Humidity 5 to 95 non condensing Alarm output rating 30VDC maximum 50mA maximum MTBF 623 377 hrs ENV GB TEMP 30 00 deg C TELCO...

Страница 6: ... www lantronix com Page 6 of 19 Power Cord Specifications Power cord specifications are provided below 27275 AC Power Cord with locking NA Line Cord Right angle Connectors NEMA 5 15P IEC 60320 C13 Length 3 ft 0 91 m Gauge 18 Jacket Type SJTW 105 C Rating 10A 125V Safety UL ...

Страница 7: ...Lantronix PS DC DUAL 5624T Power Supply Install Guide 33788 Rev E https www lantronix com Page 7 of 19 27274 AC Power Cord with locking NA Line Cord ...

Страница 8: ...Lantronix PS DC DUAL 5624T Power Supply Install Guide 33788 Rev E https www lantronix com Page 8 of 19 3344 AC Power Cord non locking NA Line Cord ...

Страница 9: ...l cycle through if one or more events alarms occur with one of these Blink Rates 1 blink per 3 seconds Fan locked no tach 2 blinks per 3 seconds Fan less than 30 PWM Pulse Width Modulation setting 3 blinks per 3 seconds 24VDC output out of spec 4 blinks per 3 seconds Exceeding 25 Deg C 5 blinks per 3 seconds Exceeding 75 Deg C If more than one alarm is set the LED will cycle through the Blink Rate...

Страница 10: ...Supply Install Guide 33788 Rev E https www lantronix com Page 10 of 19 Dimensions Power Cords Locking and non locking line cords are available AC Power Cord with locking NA Line Cord AC Power Cord with locking NA Line Cord Right angle ...

Страница 11: ...solated Power Supply with 56VDC and 24VDC Dual Output On Off switch The power on power off switch is labeled O off on FUSE The fuse can be replaced without opening the chassis see Fuse Replacement below AC INPUT Power connection labeled 100 240VAC 50 60 Hz see Connecting AC INPUT below POWER OUTPUT Terminal Block labeled 56 VDC and ALARM and 24 VDC and See Connecting POWER OUTPUT below PWR Power S...

Страница 12: ...gh Risk Activities Notice Not Designed for Use in Life Support Equipment or Applications These products are not designed for use in life support equipment or applications that would cause a life threatening situation if any such product failed Do not use this product in these types of equipment or applications Operating Temperature RESTRICTED ACCESS LOCATION A location for equipment where both of ...

Страница 13: ... Temperature 20 to 70 C Restricted 50 60 Hz 5 5A max Output Power Power 1 56VDC 315 Watts 5 6 Amps Power 2 24VDC 30 Watts 1 25 Amps Unpacking Carefully unpack the Power Supply Verify you have received the items below Save the packaging for possible future use One Power Supply One Postcard One printed Quick Start Guide 33792 One AC Power Cord option Four Rubber Feet One Snap on Ferrite TN 16210 ...

Страница 14: ...e is at least 2 inches of open space outside of at least one of the two vented sides See below 2 Hang the top of the DIN rail bracket on the DIN rail Caution The DIN Rail Spring Clip must be facing upwards as shown below 3 Click the bottom of the DIN rail bracket onto the DIN rail Grounding Connecting POWER OUTPUT Use 14 AWG stranded or better wire typ to connect to 56 VDC 315W Use 20 AWG stranded...

Страница 15: ...perature event is occurring Fuse Replacement The AC INPUT is 100 240VAC 50 60Hz 5 5A The Fuse is a 5x20mm 6 3A 250V SB slo blo externally accessible fuse Warning Disconnect all Power sources before servicing Caution Replace fuse with same Type Rating Installing TN 16210 Ferrite For EMC reasons install Snap on Ferrite TN 16210 over the 24 VDC PS DC DUAL 5624T output wires after installation 1 Open ...

Страница 16: ...LRT 33728 CLI Reference SISPM1040 384 LRT C and SISPM1040 362 LRT 33729 Application Example The example below shows a SISPM1040 384 LRT C switch Enclosure Door sensor and PS DC DUAL 5624T power supply in a single cabinet enclosure Warning Ensure that the target alarm input is capable of accepting the applied voltage 24VDC To configure Digital I O in the SISPM1040 384 LRT C via the Web UI 1 Click C...

Страница 17: ...h the technical construction on file at the above address this product carries the CE Mark I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standards s Place Minnetonka Minnesota Date July 29 2019 Signature Stephen Anderson Full Name Stephen Anderson Position Vice President of Engineering FCC Regulations NOTE This equipment has been tested a...

Страница 18: ...ique IMPORTANT Cet équipement doit être utilisé conformément aux instructions de sécurité Sähköturvallisuus TÄRKEÄÄ Tämä laite on asennettava turvaohjeiden mukaisesti Sicurezza elettrica IMPORTANTE questa apparecchiatura deve essere installata rispettando le norme di sicurezza Elektrisk sikkerhet VIKTIG Dette utstyret skal installeres i samsvar med sikkerhetsregler Segurança eléctrica IMPORTANTE E...

Страница 19: ...s 7535 Irvine Center Drive Suite100 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support 1 952 358 3601 1 800 260 1312 or techsupport transition com Sales Offices For a current list of our domestic and international sales offices go to the Lantronix web site at www lantronix com about contact ...

Отзывы: