Commands
Change Access
6 - 3
6.3 Change Access
Specifies which types of connections the serial port will accept.
Restrictions
Requires privileged user status.
Errors
Autobaud must be disabled for Dynamic and Remote ports (see Host
Applications on page 5-3).
Parameters
Local
Allows the port to initiate connections to services, and permits only local
logins.
Remote
Allows the port to accept network connection requests, but does not
permit local logins.
Dynamic
Allows the port to initiate and receive connections.
Defaults
Dynamic
See Also
6.4 Change Autobaud
Allows the port to detect the baud rate used for an incoming connection and then change its own
baud rate at login time to match that of the remote device. Incoming carriage returns help the MSS
decide the proper speed.
Restrictions
Requires privileged user status.
Does not apply to the MSS485.
Errors
Autobaud must be disabled for Dynamic and Remote port access (see
Host Applications on page 5-3).
Autobaud only works for 8 bits with no parity, or for 7 bits with Even
parity.
Default
Disabled
CHANGE ACCESS
LOCAL
REMOTE
DYNAMIC
CHANGE AUTOBAUD
DISABLED
ENABLED