Fiber Cables 

Figure 15 shows the typical construction of simplex fiber optic equipment cable. 
 

 

Figure 15: Simplex Fiber Optic Equipment Cable 

Table 3: Fiber types and common features 

Type 

Attenuation 

Bandwidth 

Dispersion Slope 

Numerical 

Aperture 

 

dB/KM@850/1300/1550  MHz-KM@850/1300nm 

ps(nm2-km) 

 

8/125 

—/0.4/0.25 

n/a 

0.093 

0.1 

50/125 

3.5/1.2/— 

400/600 

n/a 

0.20 

62.5/125 

3.5/1.2/— 

160/500 

n/a 

0.275 

100/140 

4.5/2.0/— 

200/200 

n/a 

0.29 

 

Fiber Connectors 

The following are typical connector ends for fiber cables used to connect Lantronix NIDs and media converters. 
See Figure 31 below. 

 

 

Figure 16: Fiber Optic Cable Connector Ends 

Содержание ION219 Series

Страница 1: ...ION219 x ION 19 Slot Chassis Install Guide Part Number 33412 Revision E August 2023...

Страница 2: ...AS IS Lantronix undertakes no obligation to update the information in this publication Lantronix does not make and specifically disclaims all warranties of any kind express implied or otherwise regard...

Страница 3: ...nded to be connected to intra building inside plant link segments that are not subject to lightening transients or power faults They are not to be connected to inter building outside plant link segmen...

Страница 4: ...er source e g different voltages frequencies or as redundant power For the removal of all power from the device please be aware of the following per IEC 60417 6042 2010 11 and IEC 60417 6172 2012 09 C...

Страница 5: ...allation 14 Cautions 14 Safety Considerations 14 Lifting Safety 14 Electrical Safety 14 Site Requirements 15 AC Power 15 Plant Wiring 15 Site Environment 15 Equipment Racks 15 Installation Procedures...

Страница 6: ...Cable and BNC Connectors 33 USB Universal Serial Bus 34 Cable Shield Grounding 34 Fiber Cables 35 Fiber Connectors 35 Figures Figure 1 ION219 x Chassis 8 Figure 2 Unpacking 11 Figure 3 ION219 x Chassi...

Страница 7: ...bleshoot ION slide in modules remotely via the IONMM Features Access Methods Web browser Access the ION Management Module using a standard web browser such as Internet Explorer or Mozilla Firefox Comm...

Страница 8: ...ONPS D Redundant 48VDC Power Supply for 19 Slot ION Chassis IONPS A R1 Redundant AC Power Supply for ION219 Chassis IONPS D R1 Redundant 48VDC Power Supply Module for ION19 Chassis WMBC 2RU Wall mount...

Страница 9: ...ply module provides redundancy for instant fail over Power Consumption up to 150 watts Power Source IONPS A IONPS D IONPS A R1 IONPS D R1 Dimensions Width 17 0 430mm x Depth 15 8 401mm x Height 3 5 89...

Страница 10: ...ed below ION Management Module IONMM Install Guide 33420 and User Guide 33457 ION System x323x Remotely Managed NID User Guide 33432 ION Systems CLI Reference Manual 33461 ION x222x x32xx Multi port N...

Страница 11: ...ck all ION219 x contents 2 Verify receipt of all ION219 x components Contact your sales representative if any items are missing 3 Place the ION219 x and related materials near the install location 4 S...

Страница 12: ...quired The IONMM connects to the chassis backplane and communicates with the individual installed SICs The IONMM controls the specific features and functions of each SIC The ION219 x allows the networ...

Страница 13: ...Rear The ION219 x is equipped with an AC power supply or an optional DC power supply installed in one of its rear slots An extra installation space is available for an optional AC or DC power supply...

Страница 14: ...unplug all power cords before installing or removing the chassis Keep the chassis area clear and dust free during and after installation Keep tools and chassis components away from walk areas DO NOT...

Страница 15: ...ing electromagnetic interference EMI and connector capability When wires are run from any significant distance in an electromagnetic field interference can occur between the field and the signal on th...

Страница 16: ...C 122 F When installing the ION219 x chassis in a closed or multiunit rack assembly the operating ambient temperature of the rack environment could be greater than room ambient Note Reliably groundin...

Страница 17: ...g 1 Determine the preferred alignment of the chassis into the rack 2 Using a Phillips screwdriver remove the six 6 cover to frame screws three on each side of the chassis See Figure 7 below 3 Align th...

Страница 18: ...les in the rack as shown in Figure 8 below 3 Install two 2 screws through the right bracket into the right mounting rail and two 2 screws through the left bracket into the left mounting rail using the...

Страница 19: ...stallations or to an alternate approved grounding system if required for non telecom installations Be sufficiently low in impedance to conduct fault currents likely to be present on the chassis Enable...

Страница 20: ...placing the two hole compression type connector onto the grounding lugs and then fasten with the appropriate lock washers and lug nuts at the proper torque See Figure 10 below 3 Attach the opposite e...

Страница 21: ...switch in the ON position The number designations associated with the LED on the chassis are as follows PS1 refers to the power supply installed in the left primary slot when looking at the chassis f...

Страница 22: ...ement Optional AC or DC Power Supply Module Dual Power Supplies Removing Blank Plate Slot Cover and Power Supply Module Installation Secondary Slot See the related ION Power Supply User Guide e g IONP...

Страница 23: ...the occasional monitoring of the status LED indicators on the chassis and on the installed SICs SIC Monitoring The IONMM and each SIC have one or more LED indicators to help monitor the ION219 x chass...

Страница 24: ...he Replace the Fuse section of the Install Guide for the proper method to replace the Power Supply fuse Contact Technical Support YES Contact Technical Support 3 When a problem or exception occurs the...

Страница 25: ...ibe any action s already taken to resolve the problem e g changing mode resetting etc _________________________________________________________________________________________ ________________________...

Страница 26: ...ix com ion219 chassis firmware download request to get the correct version of the firmware for your chassis Compliance Information FCC Regulations This equipment has been tested and found to comply wi...

Страница 27: ...ke adequate measures Achtung Dieses ist ein Ger t der Funkst rgrenzwertklasse A In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkst rungen auftreten In diesem F ll ist der Benutzer f r Gegen...

Страница 28: ...Lantronix ION219 x Install Guide 33412 Rev E https www lantronix com 28 UK Declaration of Conformity...

Страница 29: ...Lantronix ION219 x Install Guide 33412 Rev E https www lantronix com 29 EU Declaration of Conformity...

Страница 30: ...Lantronix ION219 x Install Guide 33412 Rev E https www lantronix com 30 North America and EU Declaration of Conformity...

Страница 31: ...worden ge nstalleerd S curit lectrique IMPORTANT Cet quipement doit tre utilis conform ment aux instructions de s curit S hk turvallisuus T RKE T m laite on asennettava turvaohjeiden mukaisesti Sicure...

Страница 32: ...network RJ 45 Pin out Pin 1 TD Pin 2 TD Pin 3 RD Pin 6 RD All pin pairs 1 2 3 6 4 5 7 8 are active in a Gigabit Ethernet network See Figure 27 below Use only dedicated wire pairs for the active pins e...

Страница 33: ...DS3 E1 and 10Base 2 Ethernet The impedance of the coaxial cable is determined by the interface type for example 75 ohm for DS3 50 ohm for 10Base 2 Ethernet Coax cable length is dependent upon applicat...

Страница 34: ...ite Data 3 D Green Data 4 GND Black Ground Figure 14 USB Peripheral and Cable Ends Cable Shield Grounding Media converter network cabling can be shielded or unshielded Shielded cables must be grounded...

Страница 35: ...n features Type Attenuation Bandwidth Dispersion Slope Numerical Aperture dB KM 850 1300 1550 MHz KM 850 1300nm ps nm2 km 8 125 0 4 0 25 n a 0 093 0 1 50 125 3 5 1 2 400 600 n a 0 20 62 5 125 3 5 1 2...

Страница 36: ...iscovery Suite 250 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support Online https www lantronix com technical support Sales Offices For a current list of...

Отзывы: