Lantronix Support
For technical support queries, visit
http://www.lantronix.com/support
For SIM card management, visit the Lantronix Connectivity Services SIM Management Portal
https://connectivity.lantronix.com
G520 LTE Connectivity Kit Quick Start Guide
©2022 Lantronix, Inc. All rights reserved. Lantronix is a registered trademark of Lantronix, Inc. SLC and SLB are trademarks of Lantronix, Inc. All other trademarks are the property of their respective
owners. Speci
fi
cation are subject to change without notice. 895-0064-00 Rev A
3. CONNECT TO LANTRONIX SLC 8000 ADVANCED CONSOLE MANAGER / SLB BRANCH OFFICE MANAGER
The G520 series failover feature requires that both Ethernet ports be configured with a static IP address. Using the included Cat
5 Ethernet cable, connect the G520 series gateway to the Ethernet2 (Eth2) connection of your SLC 8000 or SLB console unit. To
complete your G520 series gateway set up, you may need to upgrade your SLC or SLB firmware to the appropriate version. (Minimum
firmware version: SLC 8000: 8.8.0.0; SLB: 7.6.0.0)
Log into your Lantronix SLB or SLC 8000 console web
manager. From the
Network
tab, change the Eth2 settings
to “Specify” and enter the
IP address
and
Subnet Mask
shown below. It is also a best practice to “Specify” a
static IP address on the Eth1 interface for proper fail-over
functionality.
NOTE: When Eth2 is used as the Fail-over Port,
Eth2 must be in the same subnet as the selected Fail-over
Device, Lantronix G52x Series Fail-over Gateway IP Address,
i.e. 192.168.1.20/24.
Under
Fail-Over Settings,
set
IP address to Ping
to a
remote host accessible only over Ethernet1 on your
network. When this IP address is unreachable, the SLC
or SLB will fail-over to the Gateway connected to the
Eth2 port.
Click
Apply
to accept changes. The SLC/SLB will make
the setting changes and your G520 series gateway will
reboot. This process typically takes from 2-5 minutes.
Fail-over is now enabled to your G520 series gateway.
1
5
6
li k
l
h
h
ill
k
From the
Network
tab,
Fail-Over Cellular Gateway
Configuration
section, select
Fail-over Device:
“Lantronix
G52x” in the drop-down menu. Next, enter
APN of Mobile
Carrier
for SIM card provided by your mobile carrier.
Next select the
Reboot Gateway When Making Changes
toggle.
If a PIN is required, select the
PIN Lock
toggle and enter
appropriate PIN. Otherwise leave blank.
2
The default Admin user name is automatically entered.
Enter the password of the G520 series gateway.
3
Under
Fail-Over Settings
- Enter the
Fail-over Gateway
IP Address
as:
192.168.1.1.
This is the IP address of
the G520 series gateway.
4