G520 LTE Connectivity Kit Quick Start Guide

©2022 Lantronix, Inc. All rights reserved. Lantronix is a registered trademark of Lantronix, Inc. SLC and SLB are trademarks of Lantronix, Inc. All other trademarks are the property of their respective 
owners. Speci

fi

 cation are subject to change without notice. 895-0064-00 Rev A

3. CONNECT TO LANTRONIX SLC 8000 ADVANCED CONSOLE MANAGER / SLB BRANCH OFFICE MANAGER

The G520 series failover feature requires that both Ethernet ports be configured with a static IP address. Using the included Cat 

5 Ethernet cable, connect the G520 series gateway to the Ethernet2 (Eth2) connection of your SLC 8000 or SLB console unit. To 

complete your G520 series gateway set up, you may need to upgrade your SLC or SLB firmware to the appropriate version. (Minimum 

firmware version: SLC 8000: 8.8.0.0; SLB: 7.6.0.0)

Log into your Lantronix SLB or SLC 8000 console web 

manager. From the 

Network 

tab, change the Eth2 settings 

to “Specify” and enter the 

IP address

 and 

Subnet Mask

shown below. It is also a best practice to “Specify” a 

static IP address on the Eth1 interface for proper fail-over 

functionality. 

NOTE: When Eth2 is used as the Fail-over Port, 

Eth2 must be in the same subnet as the selected Fail-over 

Device, Lantronix G52x Series Fail-over Gateway IP Address, 

i.e. 192.168.1.20/24.

Under 

Fail-Over Settings,

 set 

IP address to Ping

 to a 

remote host accessible only over Ethernet1 on your 
network. When this IP address is unreachable, the SLC 
or SLB will fail-over to the Gateway connected to the 
Eth2 port. 

Click 

Apply

 to accept changes. The SLC/SLB will make 

the setting changes and your G520 series gateway will 
reboot. This process typically takes from 2-5 minutes. 
Fail-over is now enabled to your G520 series gateway. 

1

5

6

li k

l

h

h

ill

k

From the 

Network

 tab, 

Fail-Over Cellular Gateway 

Configuration

 section, select 

Fail-over Device:

 “Lantronix 

G52x” in the drop-down menu. Next, enter 

APN of Mobile 

Carrier

 for SIM card provided by your mobile carrier. 

Next select the 

Reboot Gateway When Making Changes

toggle.

If a PIN is required, select the 

PIN Lock 

toggle and enter 

appropriate PIN. Otherwise leave blank.

2

The default Admin user name is automatically entered. 
Enter the password of the G520 series gateway.

3

Under 

Fail-Over Settings

 - Enter the 

Fail-over Gateway 

IP Address

 as: 

192.168.1.1.

 This is the IP address of 

the G520 series gateway.

4