32
sys admin>>MODEM
Enter accepts present value
Init string | > ATB2H0
Save changes and update modem card? Yes or No: No>yes
Modem card not installed in slot A, init string saved
Sys admin>MODEM /DEFAULT
Current modem init string is: ATB2H0
Set modem to factory default value of: ATH0S0=1
(write out YES) Yes or No: No>yes
Modem card not installed in slot A, init string saved
sys admin>>
The sys admin may also reset the initialization string to the default value by entering the
command with the default qualifier in the form
MODEM /DEFAULT
. When using the
/DEFAULT
qualifier, the current initialization string is displayed, along with the factory
default string. The sys admin is asked to confirm the use of the default modem string;
typing
YES
and
<ENTER>
will send the default initialization string immediately to the
modem card, while typing
NO
and
<ENTER>
keeps the old modem string.
It is recommended that the default modem initialization string be used unless the
application requires that it be changed. The default initialization string is
ATH0S0=1
,
which disconnects any active phone connections when the initialization string is sent,
and sets the modem to auto-answer on one ring.
6.7 Status
Commands
There are six commands which allow the sys admin to check the status of the
ConsoleServer 3200:
CONNECTIONS
,
LISTCARDS
,
VERSION
,
INFO
,
POWERSTATUS
and
LOG
.
6.7.1
CONNECTIONS
CONNECTIONS
CONNECTIONS
CONNECTIONS
Command
The sys admin may monitor the status of connections made through the terminal cards
by using the
CONNECTIONS
command. This command will display all the active
connections and the mode of those connections as follows: