GNSS Receiver Module A5135-H User Guide
28
9 Quality and Reliability
9.1 Environmental Conditions
Operating temperature
-40°C … +85
°
C
Operating humidity
Max. 85% r. H., non-condensing, at 85
°
C
MSL JEDEC (Moisture Sensitivity Level) 3
Storage
6 months in original package
Table 9: Environmental conditions
9.2 Product Qualification
Prior to product qualification the GPS+GLONASS receiver is preconditioned ac-
cording to EIA/JEDEC standard JESD22-A113-B / Level 3.
Basic qualification tests:
•
MSL Classification according to J-STD-020C (MSL3 @ 245°C)
(Refer to report: SZRL2011110048)
•
MSL Rework Compatibility according to J-STD-020C
(Refer to report: SZRL2011110048)
•
Temperature Cycling –40°C … +85
°
C
•
Temperature Humidity Bias 70
°
C / 85% RH
•
Low / High Temperature Operating –40°C / +85
°
C
•
High Temperature Operating Life +85
°
C
•
Vibration Variable Frequency
•
Mechanical Shock
Please contact Lantronix for detailed information.
9.3 Production Test
Each module is electrically tested prior to packing and shipping to ensure state of
the art GPS+GLONASS receiver performance and accuracy.