12: Maintenance
SLB™ Branch Office Manager User Guide
238
3. Click the
Run Diagnostics
Figure 12-8 Diagnostics Report
4. To email this report, follow the instructions in
Emailing Logs and Reports (on page 241)
.
Diagnostic Commands
Go to
Diagnostic Commands (on page 295)
to view CLI commands which correspond to the web
page entries described above.
Status/Reports
Send Packet
This option sends an Ethernet packet out one of the Ethernet ports, mainly as a network
connectivity test. For UDP, the number of times the string is sent is equal to the number
of packets sent. For TCP, the number of times the string is sent may (or may not) be
equal to the number of packets sent, because TCP controls how data is packetized and
sent out. Enter the following:
Protocol:
Select the type of packet to send (
TCP
or
UDP
).
Hostname:
Specify a host name or IPaddress of the host to send the packet to.
Port:
Specify a
TCP
or
UDP
port number of the host to send the packet to.
String:
Enter a set of up to 64 characters. The string is encapsulated in the packet (so
you could use a network sniffer to track the packet and, by looking at its contents,
verify that it was sent).
Count:
The count is the number of times the string is sent.
Loopback
Specify loopback information:
Device Port
Select either an
Internal
or
External
test
SLB Internals
Select to display information on the internal memory, storage and processes of the SLB.
Содержание 100-120 VAC SLB
Страница 114: ...8 Device Ports SLB Branch Office Manager User Guide 114 Figure 8 4 Device Ports Settings ...
Страница 131: ...8 Device Ports SLB Branch Office Manager User Guide 131 Figure 8 10 Devices Power Outlets ...
Страница 174: ...9 USB Port SLB Branch Office Manager User Guide 174 Figure 9 3 Devices USB Modem ...
Страница 227: ...12 Maintenance SLB Branch Office Manager User Guide 227 Figure 12 1 Maintenance Firmware Configurations ...