Lantech LGS-1104 Скачать руководство пользователя страница 13

 

9

 

 

Two 4 10/100/1000T + 1 Mini-GBIC Web Managed Switches with PCs, print 

server, and local server attached, are both connected to the core switch. All the 

devices in this network can communicate with each other through the 4 

10/100/1000T + 1 Mini-GBIC Web Managed Switch. Connecting servers to the 4 

10/100/1000T + 1 Mini-GBIC Web Managed Switch allows users accessing the 

data on server. By using fiber ports to connect switches, the distance between 

two switches depends on the type of fiber transceiver. 

Содержание LGS-1104

Страница 1: ...Lantech LGS 1104 4 10 100 1000T 1 MINI GBIC Web Managed Switch User Manual Rev 1 20 24 Dec 2007...

Страница 2: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...

Страница 3: ...el 5 LED Indicators 5 Desktop Installation 7 Attaching Rubber Feet 7 Power On 7 NETWORK APPLICATION 8 Small Workgroup 8 Segment Bridge 8 WEB BASED MANAGEMENT 10 About Web based Management 10 System Lo...

Страница 4: ...28 Factory Default 28 Firmware Upload 28 Configuration Upload Download 29 TROUBLESHOOTING 31 Incorrect connections 31 Faulty or loose cables 31 Non standard cables 31 Improper Network Topologies 32 Di...

Страница 5: ...rce address in a 8K entry MAC address table The 4 10 100 1000T 1 Mini GBIC Web Managed Switch has 4 auto sensing 10 100 1000 Base TX RJ 45 ports 1 MINI GBIC slot that enables extended distance connect...

Страница 6: ...r system default Default IP 192 168 16 1 Gateway 192 168 16 254 Subnet Mask 255 255 255 0 Port Trunk IEEE802 3ad port trunk with link aggregation control protocol LACP The trunk group up to 2 and maxi...

Страница 7: ...t below 4 10 100 1000T 1 Mini GBIC Web Managed Switch DC Power Cord Four Rubber Pads User Manual 4 10 100 1000T 1 Mini GBIC Four Rubber Pads Web Managed Switch DC Power Adapter User Manual Package Con...

Страница 8: ...l dimension is 165 x 100 x 32 5 mm W x D x H Front Panel The Front Panel of the 4 10 100 1000T 1 Mini GBIC Web Managed Switch consists of LED Indicators and a reset button Please refer to LED Indicato...

Страница 9: ...to a workstation or PC Therefore Auto MDI MDIX would allow connecting to another Switch or workstation without changing non crossover or crossover cabling Mini GBIC slot The appropriate replaceable Mi...

Страница 10: ...nnected with the device Blinks Green The port is in processing of receiving or transmitting data Off No device attached FDX COL On Yellow The port is operating in Full duplex mode Blinks Yellow Collis...

Страница 11: ...ace on the bottom of the switch is grease and dust free B Remove adhesive backing from your Rubber Pads C Apply the Rubber Feet to each corner on the bottom of the switch These footpads can prevent th...

Страница 12: ...nd forward all traffic based on the destination address By using Uplink port the switch can connect with another switch or hub to interconnect other small switched workgroups to form a larger switched...

Страница 13: ...e devices in this network can communicate with each other through the 4 10 100 1000T 1 Mini GBIC Web Managed Switch Connecting servers to the 4 10 100 1000T 1 Mini GBIC Web Managed Switch allows users...

Страница 14: ...ugh a standard browser such as Microsoft Internet Explorer The Web Based Management supports Internet Explorer 6 0 And it is applied with Java Applets for reducing network bandwidth consumption enhanc...

Страница 15: ...ays the unique hardware address assigned by manufacturer default S W Version Displays the Software Version of Kernel H W Version Displays the Hardware Version of the switch Active IP Address Displays...

Страница 16: ...t switch boots and the lease is 50 or more passed the client switch will attempt to renew the lease At 87 5 of the lease completion the client switch will attempt to contact any DHCP server for a new...

Страница 17: ...The default password is root Inactivity Timeout Set the timeout period for security in number between 10 and 10000 seconds And then click Apply to have the configuration take effect Or click Refresh t...

Страница 18: ...ration before Applying Port Configuration interface Statistics 1 Overview The following information provides the current port statistic information Press Clear button to clean all counts and then clic...

Страница 19: ...which would allow users to isolate network traffic and therefore only the members of the VLAN will receive traffic from the members of the same VLAN Basically creating a VLAN from a switch is logicall...

Страница 20: ...arch Vlan Entry Vlan ID and then press Search VLAN Setting interface VLAN Port Setting Click VLAN Port Setting to bring up the configuration interface for adjusting the VID Setting PVID Enter the Port...

Страница 21: ...the newest state VLAN Port Setting interface Port Trunk Port trunk allows multiple links to be bundled together and act as a single physical link for increased throughput It provides load balancing an...

Страница 22: ...nk interface LACP Setting The Link Aggregation Control Protocol LACP is a computer networking term and is part of IEEE specification 802 3ad that allows bundling several physical ports together to for...

Страница 23: ...e configuration take effect Or click Refresh to refresh the configuration to view the newest state LACP Setting interface LACP Status When the LACP aggregator has been set up the LACP status informati...

Страница 24: ...pports STP and the system will automatically detect the connected device that is running STP or RSTP protocol RSTP System Configuration System Priority A value used to identify the root bridge The bri...

Страница 25: ...e amount of time that protocol information received on a port is stored by the switch Forward Delay Time 4 30 The number of seconds from 4 30 which determines how long each of the listening and learni...

Страница 26: ...e port as an edge port tick the check box Path Cost The cost of the path to the other bridge from this transmitting bridge at the specified port Enter a number 1 through 200 000 000 Click Apply to hav...

Страница 27: ...DIUS Secret Set an encryption key for authenticating usage sessions with the specified radius server This key must match the encryption key used on the Radius Server Admin State Select the state of po...

Страница 28: ...ent re authentication and how often it occurs Reauthentication Enable Enable the re authentication mode Reauthentication Period 1 3600 seconds Set the period of time in second between re authenticatio...

Страница 29: ...gure QoS mode port priority TOS and COS priority setting Mode Specify the QoS mode port DSCP or vlantag Port Priority Select the priority level low normal medium or high Click Apply to have the config...

Страница 30: ...is set as DSCP mode and DSCP level 25 is set as high When the packet is received via port 1 the system will check the DSCP value of the received IP packet If the DSCP value of the received IP packet i...

Страница 31: ...ag Mapping to enter VLAN tag priority configuration interface Set the VLAN tag priority level from 0 7 for each port Click Apply to have the configuration take effect Press Refresh to refresh the conf...

Страница 32: ...Factory Default Reset the switch to default configuration Click Yes to reset all the configurations to factory default value Factory Default interface Firmware Upload The system provides the Web GUI f...

Страница 33: ...ownload The system provides the Web GUI configuration file transfer function which would allow user to backup and restore the switch configuration Click Browse to locate the file And then press Upload...

Страница 34: ...30 For restoring the configuration press Download to restore the file Configuration Download interface...

Страница 35: ...then the link will fail For fiber connection please notice that fiber cable mode and fiber module should match Faulty or loose cables Look for loose or obviously faulty connections If they appear to b...

Страница 36: ...oops Between any two ends nodes there should be only one active cabling path at any time Data path loops will cause broadcast storms that will severely impact network performance Diagnosing LED Indica...

Страница 37: ...and Back pressure IEEE 802 1d Spanning Tree IEEE 802 1w Rapid Spanning Tree IEEE 802 3ad Port trunk with LACP IEEE 802 1p Class of Service IEEE 802 1x user authentication IEEE802 1Q VLAN Tagging Prot...

Страница 38: ...cable EIA TIA 568 100 ohm 100M Connector Gigabit copper 4 x RJ 45 with Auto MDIX MINI GBIC 1 x MINI GBIC socket 3 3v Back plane 10Gbps MAC address 8K Memory Buffer 112Kbytes Jumbo packet Supports 8Kb...

Страница 39: ...35 Operating Humidity 10 to 90 Non condensing EMI FCC Class A CE Safety UL cUL...

Страница 40: ...olarity of the wires that make up each wire pair The table below shows the 10 100BASE TX MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data plus TD...

Страница 41: ...37 Straight through cable schematic Cross over cable schematic 10 100 1000Base TX Pin outs The following figure shows the 10 100 1000 Ethernet RJ 45 pin outs...

Страница 42: ...38 10 100 1000Base TX Cable Schematic Straight through cables schematic Cross over cables schematic...

Отзывы: